Double opposite end injection capillary electrophoresis with contactless conductometric detection for simultaneous determination of chloride, sodium and potassium in cystic fibrosis diagnosis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F14%3A00062633" target="_blank" >RIV/65269705:_____/14:00062633 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14740/14:00074081
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.chroma.2014.06.091" target="_blank" >http://dx.doi.org/10.1016/j.chroma.2014.06.091</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2014.06.091" target="_blank" >10.1016/j.chroma.2014.06.091</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Double opposite end injection capillary electrophoresis with contactless conductometric detection for simultaneous determination of chloride, sodium and potassium in cystic fibrosis diagnosis
Popis výsledku v původním jazyce
A novel approach for diagnosis of cystic fibrosis is presented. A simple and fast procedure to obtain sweat sample was developed. It consists of repeatedly wiping the skin of the forearm with deionized water moisturized cotton swab and extraction in 1 mLof deionized water. Double opposite end injection capillary electrophoresis with contactless conductometric detection is used for the analysis of the extract. Chloride, sodium and potassium as the three target ions that participate in the ion transfer across the cellular membranes, and are affected by CF, are simultaneously determined in approximately 3 min in a background electrolyte containing 20 mM 2-(N-morpholino)ethanesulfonic acid, 20 mM L-histidine and 2 mM 18-crown-6. By using the target ion ratios rather than the concentrations of each individual ion combined with principal component analysis, the diagnosis of CF can be made more accurately and greatly reduce the number of false positive or negative results as is often the cas
Název v anglickém jazyce
Double opposite end injection capillary electrophoresis with contactless conductometric detection for simultaneous determination of chloride, sodium and potassium in cystic fibrosis diagnosis
Popis výsledku anglicky
A novel approach for diagnosis of cystic fibrosis is presented. A simple and fast procedure to obtain sweat sample was developed. It consists of repeatedly wiping the skin of the forearm with deionized water moisturized cotton swab and extraction in 1 mLof deionized water. Double opposite end injection capillary electrophoresis with contactless conductometric detection is used for the analysis of the extract. Chloride, sodium and potassium as the three target ions that participate in the ion transfer across the cellular membranes, and are affected by CF, are simultaneously determined in approximately 3 min in a background electrolyte containing 20 mM 2-(N-morpholino)ethanesulfonic acid, 20 mM L-histidine and 2 mM 18-crown-6. By using the target ion ratios rather than the concentrations of each individual ion combined with principal component analysis, the diagnosis of CF can be made more accurately and greatly reduce the number of false positive or negative results as is often the cas
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1358
Číslo periodika v rámci svazku
September
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
293-298
Kód UT WoS článku
000340979200035
EID výsledku v databázi Scopus
—