Changes in Hematologic and Coagulation Profiles in Rabbits with Right-ventricle Pacing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F16%3A00065945" target="_blank" >RIV/65269705:_____/16:00065945 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1515/folmed-2016-0013" target="_blank" >http://dx.doi.org/10.1515/folmed-2016-0013</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1515/folmed-2016-0013" target="_blank" >10.1515/folmed-2016-0013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Changes in Hematologic and Coagulation Profiles in Rabbits with Right-ventricle Pacing
Popis výsledku v původním jazyce
Objectives: The aim of this study was to evaluate changes in hematology and coagulation in rabbits with right-ventricle pacing without medication. Animals and methods: Blood was collected from ten non-anesthetized male rabbits from the jugular vein before and one month after pacemaker placement. Total erythrocyte, leukocyte and platelet count, hemoglobin, hematocrit and diff erential leukocyte count were done on automatic veterinary flow cytometry hematologic analyzer. Prothrombin time, activated partial thromboplastin time, fibrinogen level, D-dimers and kaolin-activated thromboelastography was measured from citrated blood.Results: We found an increase in red blood cell mass and decrease in platelet count, while coagulation tests did not diff er between samplings.
Název v anglickém jazyce
Changes in Hematologic and Coagulation Profiles in Rabbits with Right-ventricle Pacing
Popis výsledku anglicky
Objectives: The aim of this study was to evaluate changes in hematology and coagulation in rabbits with right-ventricle pacing without medication. Animals and methods: Blood was collected from ten non-anesthetized male rabbits from the jugular vein before and one month after pacemaker placement. Total erythrocyte, leukocyte and platelet count, hemoglobin, hematocrit and diff erential leukocyte count were done on automatic veterinary flow cytometry hematologic analyzer. Prothrombin time, activated partial thromboplastin time, fibrinogen level, D-dimers and kaolin-activated thromboelastography was measured from citrated blood.Results: We found an increase in red blood cell mass and decrease in platelet count, while coagulation tests did not diff er between samplings.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT14591" target="_blank" >NT14591: Plazmatické markry aktivace koagulace u pacientů se zavedenou endokardiální elektrodou</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů