A comparative analysis of different automated von Willebrand factor glycoprotein Ib-binding activity assays in well typed von Willebrand disease patients
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F18%3A00069284" target="_blank" >RIV/65269705:_____/18:00069284 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/18:00104167
Výsledek na webu
<a href="http://dx.doi.org/10.1111/jth.14145" target="_blank" >http://dx.doi.org/10.1111/jth.14145</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1111/jth.14145" target="_blank" >10.1111/jth.14145</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A comparative analysis of different automated von Willebrand factor glycoprotein Ib-binding activity assays in well typed von Willebrand disease patients
Popis výsledku v původním jazyce
Background: von Willebrand disease (VWD) is an inherited bleeding disorder caused by quantitative (type 1 and 3) or qualitative (type 2) von Willebrand factor (VWF) defect. VWD diagnosis and classification require numerous laboratory tests. VWF: glycoprotein Ib (GPIb)-binding activity assays are used to distinguish type 1 from type 2 VWD. Objectives: Three different automated VWF:GPIb-binding activity assays were compared. Patients and methods: BC-VWF:RCo (Siemens Healthcare Diagnostics), HemosIL((R)) VWF:RCo (Instrumentation Laboratory) and INNOVANCE((R)) VWF:Ac (Siemens Healthcare Diagnostics) were performed in a well typed VWD cohort (n = 142). Results: Based on the three most used VWD parameters (FVIII:C, VWF:Ag and VWF:GPIb-binding activity) and using a cut-off of <0.70 for type 2 VWD revealed sensitivity and specificity of, respectively, 92% and 72.4% for VWF:RCo/VWF:Ag, 84% and 89.7% for VWF:GPIbR/VWF:Ag, and 92% and 85.1% for VWF:GPIbM/VWF:Ag, whereas a lowered cut-off of < 0.60 resulted in reduced sensitivity with increased specificity for all assays. Conclusion: VWD classification based on FVIII:C, VWF:Ag and VWF:GPIb-binding activity revealed an overall problem with normal VWF:GPIb-binding activity/VWF:Ag within type 2, especially type 2A/IIE. Although all assays were practically identical, BC-VWF:RCo had higher %CV compared with both new assays but comparable lower limit of quantification (LLOQ) similar to 4 IU dL(-1). No clear improved distinction between type 1 and 2 VWD with new assays was seen. BC-VWF:RCo and HemosIL((R)) are ristocetin dependent, whereas INNOVANCE((R)) does not rely upon ristocetin and is not influenced by VWF polymorphisms increasing VWF:GPIb-binding activity levels. INNOVANCE((R)) seems to be the best choice as a first-line VWF:GPIb-binding activity assay, providing the best balance between sensitivity and specificity for type 2 VWD.
Název v anglickém jazyce
A comparative analysis of different automated von Willebrand factor glycoprotein Ib-binding activity assays in well typed von Willebrand disease patients
Popis výsledku anglicky
Background: von Willebrand disease (VWD) is an inherited bleeding disorder caused by quantitative (type 1 and 3) or qualitative (type 2) von Willebrand factor (VWF) defect. VWD diagnosis and classification require numerous laboratory tests. VWF: glycoprotein Ib (GPIb)-binding activity assays are used to distinguish type 1 from type 2 VWD. Objectives: Three different automated VWF:GPIb-binding activity assays were compared. Patients and methods: BC-VWF:RCo (Siemens Healthcare Diagnostics), HemosIL((R)) VWF:RCo (Instrumentation Laboratory) and INNOVANCE((R)) VWF:Ac (Siemens Healthcare Diagnostics) were performed in a well typed VWD cohort (n = 142). Results: Based on the three most used VWD parameters (FVIII:C, VWF:Ag and VWF:GPIb-binding activity) and using a cut-off of <0.70 for type 2 VWD revealed sensitivity and specificity of, respectively, 92% and 72.4% for VWF:RCo/VWF:Ag, 84% and 89.7% for VWF:GPIbR/VWF:Ag, and 92% and 85.1% for VWF:GPIbM/VWF:Ag, whereas a lowered cut-off of < 0.60 resulted in reduced sensitivity with increased specificity for all assays. Conclusion: VWD classification based on FVIII:C, VWF:Ag and VWF:GPIb-binding activity revealed an overall problem with normal VWF:GPIb-binding activity/VWF:Ag within type 2, especially type 2A/IIE. Although all assays were practically identical, BC-VWF:RCo had higher %CV compared with both new assays but comparable lower limit of quantification (LLOQ) similar to 4 IU dL(-1). No clear improved distinction between type 1 and 2 VWD with new assays was seen. BC-VWF:RCo and HemosIL((R)) are ristocetin dependent, whereas INNOVANCE((R)) does not rely upon ristocetin and is not influenced by VWF polymorphisms increasing VWF:GPIb-binding activity levels. INNOVANCE((R)) seems to be the best choice as a first-line VWF:GPIb-binding activity assay, providing the best balance between sensitivity and specificity for type 2 VWD.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30205 - Hematology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of thrombosis and haemostasis
ISSN
1538-7933
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
1268-1277
Kód UT WoS článku
000437289500005
EID výsledku v databázi Scopus
2-s2.0-85049500253