Duodenum sparing technique for preventive stenting of biliary tract anastomosis in pigs
Popis výsledku v původním jazyce
The main aim of this study was to find a standardized method for preventive stenting of biliary tract anastomosis with biodegradable self-expandable stent from polydioxanone and to evaluate the functionality of the stent. The experimental study was conducted using four pigs with a follow-up of eight weeks. The procedure was done under general anaesthesia. The function of the stent was verified by clinical stage, blood test, magnetic resonance cholangiopancreatography and necropsy. Our duodenum sparing technique was described in detail and photographically documented. All pigs finished the follow-up period without clinical, laboratory or radiologic signs of biliary obstruction. Necropsy did not reveal complication of the procedure or anastomotic stricture. In conclusion, this study demonstrated a simple new duodenum sparing method of transanastomotic insertion of a biodegradable self-expandable stent from polydioxanone. We did not find any complications during the follow-up. This method will be used in our follow-up study with an extended experimental control group of animals and a longer follow-up period to verify the preventive functionality of this stent.
Název v anglickém jazyce
Duodenum sparing technique for preventive stenting of biliary tract anastomosis in pigs
Popis výsledku anglicky
The main aim of this study was to find a standardized method for preventive stenting of biliary tract anastomosis with biodegradable self-expandable stent from polydioxanone and to evaluate the functionality of the stent. The experimental study was conducted using four pigs with a follow-up of eight weeks. The procedure was done under general anaesthesia. The function of the stent was verified by clinical stage, blood test, magnetic resonance cholangiopancreatography and necropsy. Our duodenum sparing technique was described in detail and photographically documented. All pigs finished the follow-up period without clinical, laboratory or radiologic signs of biliary obstruction. Necropsy did not reveal complication of the procedure or anastomotic stricture. In conclusion, this study demonstrated a simple new duodenum sparing method of transanastomotic insertion of a biodegradable self-expandable stent from polydioxanone. We did not find any complications during the follow-up. This method will be used in our follow-up study with an extended experimental control group of animals and a longer follow-up period to verify the preventive functionality of this stent.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30212 - Surgery
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Veterinaria Brno
ISSN
0001-7213
e-ISSN
—
Svazek periodika
88
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
287-"+"
Kód UT WoS článku
000509757500005
EID výsledku v databázi Scopus
—