Retroauricular Emphysema as a Late Complication After Bonebridge Implantation: Case Report
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F21%3A00074224" target="_blank" >RIV/65269705:_____/21:00074224 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/21:00121388
Výsledek na webu
<a href="https://journals.sagepub.com/doi/pdf/10.1177/01455613211000299" target="_blank" >https://journals.sagepub.com/doi/pdf/10.1177/01455613211000299</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/01455613211000299" target="_blank" >10.1177/01455613211000299</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Retroauricular Emphysema as a Late Complication After Bonebridge Implantation: Case Report
Popis výsledku v původním jazyce
Bonebridge (BB) is the first active implantation system for bone conduction that is placed fully under the skin. Experience suggests that BB is characterized by low incidence of postoperative complications. This case report presents a rare case of a 16-year-old girl with incidence of emphysema occurring over the implant 1 year after operation. We performed a computed tomography scan that showed pockets of gas above the floating mass transducer so we provided the revision surgery and sealed the artificial opening with fat from the earlobe and fibrin glue. Since that time, no air has collected in the retroauricular area and the implant has been fully functional.
Název v anglickém jazyce
Retroauricular Emphysema as a Late Complication After Bonebridge Implantation: Case Report
Popis výsledku anglicky
Bonebridge (BB) is the first active implantation system for bone conduction that is placed fully under the skin. Experience suggests that BB is characterized by low incidence of postoperative complications. This case report presents a rare case of a 16-year-old girl with incidence of emphysema occurring over the implant 1 year after operation. We performed a computed tomography scan that showed pockets of gas above the floating mass transducer so we provided the revision surgery and sealed the artificial opening with fat from the earlobe and fibrin glue. Since that time, no air has collected in the retroauricular area and the implant has been fully functional.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30206 - Otorhinolaryngology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ear, Nose and Throat Journal
ISSN
0145-5613
e-ISSN
—
Svazek periodika
100
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
233-236
Kód UT WoS článku
000641861200017
EID výsledku v databázi Scopus
2-s2.0-85102699325