Tele-Assessment of Functional Capacity through the Six-Minute Walk Test in Patients with Diabetes Mellitus Type 2: Validity and Reliability of Repeated Measurements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F23%3A00077831" target="_blank" >RIV/65269705:_____/23:00077831 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14110/23:00130467
Výsledek na webu
<a href="https://www.mdpi.com/1424-8220/23/3/1354" target="_blank" >https://www.mdpi.com/1424-8220/23/3/1354</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s23031354" target="_blank" >10.3390/s23031354</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Tele-Assessment of Functional Capacity through the Six-Minute Walk Test in Patients with Diabetes Mellitus Type 2: Validity and Reliability of Repeated Measurements
Popis výsledku v původním jazyce
A tele-assessed 6MWT (TL 6MWT) could be an alternative method of evaluating functional capacity in patients with diabetes mellitus type 2 (DM2). This study aimed to assess the validity and reliability of a TL 6MWT. The functional capacity of 28 patients with DM2 (75% men) aged 61 +/- 13 years was evaluated twice via an indoor, center-based 6MWT (CB 6MWT) and twice outside each patient's home via a web-based platform TL 6MWT. The study showed a high statistically significant correlation between the CB and TL 6MWT (Pearson's r = 0.76, p < 0.001). Reliability testing showed no statistically significant differences in the distance covered (CB1: 492 +/- 84 m and CB2: 506 +/- 86 m versus TL1: 534 +/- 87 m and TL2: 542 +/- 93 m, respectively) and in the best distance of the TL 6MWT (545 +/- 93 m) compared to the best CB distance (521 +/- 83 m). Strong internal reliability for both the CB (intraclass correlation coefficient (ICC) = 0.93) and the TL 6MWT (ICC = 0.98) was found. The results indicate that a TL 6MWT performed outdoors can be a highly valid and reliable tool to assess functional capacity in patients with DM2. No learning effect between the TL and CB assessment was found, minimizing the need for repetition.
Název v anglickém jazyce
Tele-Assessment of Functional Capacity through the Six-Minute Walk Test in Patients with Diabetes Mellitus Type 2: Validity and Reliability of Repeated Measurements
Popis výsledku anglicky
A tele-assessed 6MWT (TL 6MWT) could be an alternative method of evaluating functional capacity in patients with diabetes mellitus type 2 (DM2). This study aimed to assess the validity and reliability of a TL 6MWT. The functional capacity of 28 patients with DM2 (75% men) aged 61 +/- 13 years was evaluated twice via an indoor, center-based 6MWT (CB 6MWT) and twice outside each patient's home via a web-based platform TL 6MWT. The study showed a high statistically significant correlation between the CB and TL 6MWT (Pearson's r = 0.76, p < 0.001). Reliability testing showed no statistically significant differences in the distance covered (CB1: 492 +/- 84 m and CB2: 506 +/- 86 m versus TL1: 534 +/- 87 m and TL2: 542 +/- 93 m, respectively) and in the best distance of the TL 6MWT (545 +/- 93 m) compared to the best CB distance (521 +/- 83 m). Strong internal reliability for both the CB (intraclass correlation coefficient (ICC) = 0.93) and the TL 6MWT (ICC = 0.98) was found. The results indicate that a TL 6MWT performed outdoors can be a highly valid and reliable tool to assess functional capacity in patients with DM2. No learning effect between the TL and CB assessment was found, minimizing the need for repetition.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
1424-8220
Svazek periodika
23
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
12
Strana od-do
1354
Kód UT WoS článku
000930074800001
EID výsledku v databázi Scopus
2-s2.0-85147845584