First-in-Human Implantable Inferior Vena Cava Sensor for Remote Care in Heart Failure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F65269705%3A_____%2F25%3A00081827" target="_blank" >RIV/65269705:_____/25:00081827 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023884:_____/25:00010066
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S2213177925001726" target="_blank" >https://www.sciencedirect.com/science/article/pii/S2213177925001726</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jchf.2025.01.019" target="_blank" >10.1016/j.jchf.2025.01.019</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
First-in-Human Implantable Inferior Vena Cava Sensor for Remote Care in Heart Failure
Popis výsledku v původním jazyce
Background: Variations of inferior vena cava (IVC) area and collapsibility serve as early markers of congestion and predict risk for heart failure (HF) events. Objectives: The aim of this first-in-human study (FUTURE-HF [First in Human Clinical Investigation of the FIRE1 System in Heart Failure Patients]) was to evaluate the safety and feasibility of a novel implantable IVC sensor for remote management in patients with HF. This paper is the final report on primary (3-month) and exploratory (6-month) endpoints. Methods: Patients with HF hospitalizations within the previous year, with elevated natriuretic peptide levels, and on optimal HF treatment were included. The primary safety endpoints were procedural success without device- or procedure-related complications at 3 months. The primary technical endpoint was signal acquisition following implantation and at a clinic visit within 3 months. Sensor-derived IVC area was compared with computed tomography (CT)-based IVC dimensions. Patient adherence to daily readings and exploratory clinical findings at 6 months were assessed. Results: Fifty patients underwent successful implantation (mean age 65 +- 9 years, 14% women, 72% in NYHA functional class III), with 49 contributing to the primary safety and technical endpoints at 3 months. Sensor-derived IVC area demonstrated excellent agreement with CT measurement (mean absolute error 13.53 mm2 [3.55%] R2 = 0.98). Median adherence was 96% at 6-month follow-up. Exploratory analyses of clinical outcomes suggested improvements in N-terminal pro-B-type natriuretic peptide, NYHA functional class, and quality of life and reduced HF events. Conclusions: This first-in-human experience demonstrated that the implantation of an IVC sensor was safe and feasible. Sensor-derived IVC area demonstrated excellent correlation with CT-derived IVC area, and exploratory clinical outcomes suggest that this may serve as a novel tool for ambulatory management of congestion to facilitate remote care in HF. (First in Human Clinical Investigation of the FIRE1 System in Heart Failure Patients [FUTURE-HF]; NCT04203576).
Název v anglickém jazyce
First-in-Human Implantable Inferior Vena Cava Sensor for Remote Care in Heart Failure
Popis výsledku anglicky
Background: Variations of inferior vena cava (IVC) area and collapsibility serve as early markers of congestion and predict risk for heart failure (HF) events. Objectives: The aim of this first-in-human study (FUTURE-HF [First in Human Clinical Investigation of the FIRE1 System in Heart Failure Patients]) was to evaluate the safety and feasibility of a novel implantable IVC sensor for remote management in patients with HF. This paper is the final report on primary (3-month) and exploratory (6-month) endpoints. Methods: Patients with HF hospitalizations within the previous year, with elevated natriuretic peptide levels, and on optimal HF treatment were included. The primary safety endpoints were procedural success without device- or procedure-related complications at 3 months. The primary technical endpoint was signal acquisition following implantation and at a clinic visit within 3 months. Sensor-derived IVC area was compared with computed tomography (CT)-based IVC dimensions. Patient adherence to daily readings and exploratory clinical findings at 6 months were assessed. Results: Fifty patients underwent successful implantation (mean age 65 +- 9 years, 14% women, 72% in NYHA functional class III), with 49 contributing to the primary safety and technical endpoints at 3 months. Sensor-derived IVC area demonstrated excellent agreement with CT measurement (mean absolute error 13.53 mm2 [3.55%] R2 = 0.98). Median adherence was 96% at 6-month follow-up. Exploratory analyses of clinical outcomes suggested improvements in N-terminal pro-B-type natriuretic peptide, NYHA functional class, and quality of life and reduced HF events. Conclusions: This first-in-human experience demonstrated that the implantation of an IVC sensor was safe and feasible. Sensor-derived IVC area demonstrated excellent correlation with CT-derived IVC area, and exploratory clinical outcomes suggest that this may serve as a novel tool for ambulatory management of congestion to facilitate remote care in HF. (First in Human Clinical Investigation of the FIRE1 System in Heart Failure Patients [FUTURE-HF]; NCT04203576).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JACC-Heart Failure
ISSN
2213-1779
e-ISSN
2213-1787
Svazek periodika
13
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
1000-1010
Kód UT WoS článku
001506129800013
EID výsledku v databázi Scopus
2-s2.0-105002317892