Rectangular array electric current transducer with integrated fluxgate sensors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985530%3A_____%2F19%3A00523134" target="_blank" >RIV/67985530:_____/19:00523134 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21230/19:00336354
Výsledek na webu
<a href="https://www.mdpi.com/1424-8220/19/22/4964" target="_blank" >https://www.mdpi.com/1424-8220/19/22/4964</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s19224964" target="_blank" >10.3390/s19224964</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rectangular array electric current transducer with integrated fluxgate sensors
Popis výsledku v původním jazyce
Novel rectangular yokeless current transducer with the range 400 A using 16 microfluxgate sensors around the busbar conductor is presented in this paper. Compared to yokeless transducers utilizing the differential pair of magnetic sensors, our solution has much better suppression of the external currents (lower crosstalk). Compared to industrial transducers with yoke, the new transducer has 15-times lower noise, 7-times better temperature stability, and same crosstalk. Sensor design and design of current monitoring system is presented together with the results of long-term field tests. Crosstalk error is examined in dependence on the number of the operating sensors and external current position.
Název v anglickém jazyce
Rectangular array electric current transducer with integrated fluxgate sensors
Popis výsledku anglicky
Novel rectangular yokeless current transducer with the range 400 A using 16 microfluxgate sensors around the busbar conductor is presented in this paper. Compared to yokeless transducers utilizing the differential pair of magnetic sensors, our solution has much better suppression of the external currents (lower crosstalk). Compared to industrial transducers with yoke, the new transducer has 15-times lower noise, 7-times better temperature stability, and same crosstalk. Sensor design and design of current monitoring system is presented together with the results of long-term field tests. Crosstalk error is examined in dependence on the number of the operating sensors and external current position.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10508 - Physical geography
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-19877S" target="_blank" >GA17-19877S: Nové metody měření elektrických proudů</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors
ISSN
1424-8220
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
22
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
13
Strana od-do
4964
Kód UT WoS článku
000503381500143
EID výsledku v databázi Scopus
2-s2.0-85075113913