Rectangular Array Current Transducer with Integrated microfluxgate Sensors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F18%3A00328720" target="_blank" >RIV/68407700:21230/18:00328720 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/ICSENS.2018.8589563" target="_blank" >http://dx.doi.org/10.1109/ICSENS.2018.8589563</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICSENS.2018.8589563" target="_blank" >10.1109/ICSENS.2018.8589563</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rectangular Array Current Transducer with Integrated microfluxgate Sensors
Popis výsledku v původním jazyce
Novel rectangular yokeless current transducer with the range 400 A using 16 microfluxgate sensors around the busbar conductor is presented in this paper. Compared to yokeless transducers utilizing the differential pair of magnetic sensors, our solution has much better suppression of external currents (lower crosstalk). Compared to industrial transducers with yoke, the new transducer has to-times lower noise, to-times better temperature stability, and same crosstalk. Sensor design, different methods for calculating the current and temperature dependence are presented in this paper. Crosstalk error is examined in dependence on the number of the operating sensors and external current position.
Název v anglickém jazyce
Rectangular Array Current Transducer with Integrated microfluxgate Sensors
Popis výsledku anglicky
Novel rectangular yokeless current transducer with the range 400 A using 16 microfluxgate sensors around the busbar conductor is presented in this paper. Compared to yokeless transducers utilizing the differential pair of magnetic sensors, our solution has much better suppression of external currents (lower crosstalk). Compared to industrial transducers with yoke, the new transducer has to-times lower noise, to-times better temperature stability, and same crosstalk. Sensor design, different methods for calculating the current and temperature dependence are presented in this paper. Crosstalk error is examined in dependence on the number of the operating sensors and external current position.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceeding - 2018 IEEE SENSORS
ISBN
978-1-5386-4707-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE SENSORS
Místo vydání
—
Místo konání akce
Delhi
Datum konání akce
28. 10. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—