Model Consideration for Blind Source Separation of Medical Image Sequences
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985556%3A_____%2F12%3A00383332" target="_blank" >RIV/67985556:_____/12:00383332 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Model Consideration for Blind Source Separation of Medical Image Sequences
Popis výsledku v původním jazyce
The problem of functional analysis of medical image sequences is studied. The obtained images are assumed to be a superposition of images of underlying biological organs. This is commonly modeled as a Factor Analysis (FA) model. However, this model aloneallows for biologically impossible solutions. Therefore, we seek additional biologically motivated assumptions that can be incorporated into the model to yield better solutions. In this paper, we review additional assumptions such as convolution of timeactivity, regions of interest selection, and noise analysis. All these assumptions can be incorporated into the FA model and their parameters estimated by the Variation Bayes estimation procedure. We compare these assumptions and discuss their influenceon the resulting decomposition from diagnostic point of view. The algorithms are tested and demonstrated on real data from renal scintigraphy; however, the methodology can be used in any other imaging modality.
Název v anglickém jazyce
Model Consideration for Blind Source Separation of Medical Image Sequences
Popis výsledku anglicky
The problem of functional analysis of medical image sequences is studied. The obtained images are assumed to be a superposition of images of underlying biological organs. This is commonly modeled as a Factor Analysis (FA) model. However, this model aloneallows for biologically impossible solutions. Therefore, we seek additional biologically motivated assumptions that can be incorporated into the model to yield better solutions. In this paper, we review additional assumptions such as convolution of timeactivity, regions of interest selection, and noise analysis. All these assumptions can be incorporated into the FA model and their parameters estimated by the Variation Bayes estimation procedure. We compare these assumptions and discuss their influenceon the resulting decomposition from diagnostic point of view. The algorithms are tested and demonstrated on real data from renal scintigraphy; however, the methodology can be used in any other imaging modality.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BB - Aplikovaná statistika, operační výzkum
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Doktorandské dny 2012
ISBN
978-80-01-05138-2
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
1-10
Název nakladatele
ČVUT v Praze
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
16. 11. 2012
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—