Kauzalita mezi amplitudou a frekvencí srdečních oscilací
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985807%3A_____%2F04%3A00105222" target="_blank" >RIV/67985807:_____/04:00105222 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Causality between the Amplitude and Frequency of Cardiac Oscillations
Popis výsledku v původním jazyce
Using an information-theoretic approach, causality between the systolic amplitude in blood pressure and the frequency of the heart beat was analyzed. Blood pressure and ECG were noninvasively recorded in young, healthy subjects. Three successive measurements were performed: during spontaneous breathing and during paced respiration-at frequencies both higher and lower than that of spontaneous respiration. We demonstrate that the amplitude and frequency of the cardiac rhythm are synchronized for most of the time. The synchronization is stronger during paced respiration at a frequency lower than that of spontaneous breathing. Episodes where the cardiac frequency was driven by the systolic pressure were also detected during slow, paced respiration.
Název v anglickém jazyce
Causality between the Amplitude and Frequency of Cardiac Oscillations
Popis výsledku anglicky
Using an information-theoretic approach, causality between the systolic amplitude in blood pressure and the frequency of the heart beat was analyzed. Blood pressure and ECG were noninvasively recorded in young, healthy subjects. Three successive measurements were performed: during spontaneous breathing and during paced respiration-at frequencies both higher and lower than that of spontaneous respiration. We demonstrate that the amplitude and frequency of the cardiac rhythm are synchronized for most of the time. The synchronization is stronger during paced respiration at a frequency lower than that of spontaneous breathing. Episodes where the cardiac frequency was driven by the systolic pressure were also detected during slow, paced respiration.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BB - Aplikovaná statistika, operační výzkum
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Cardiovascular Engineering
ISSN
1567-8822
e-ISSN
—
Svazek periodika
4
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
127-132
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—