Srovnání metod pro měření hmotnostní koncentrace atmosférických aerosolů během kampaně INTERCOMP2000 ? vliv instrumentace a velikosti mezního průměru
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F04%3A00104985" target="_blank" >RIV/67985858:_____/04:00104985 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Intercomparison of Methods to Measure the Mass Concentration of the Atmospheric Aerosol during INTERCOMP2000-Influence of Instrumentation and Size Cuts
Popis výsledku v původním jazyce
Within the EUROTRAC-2 subproject AEROSOL, the intensive field campaign INTERCOMP2000 was conducted to compare aerosol samplers and methods to measure various aerosol properties. Here a comparison of mass concentrations measured with different PM2.5 and PM10 samplers as well as cascade impactors is described. Different filter types were used. In general, the PM2.5 and PM10 mass concentrations obtained on filters agree well. The data agree within 18.1% (PM2.5, all data). If data obtained with the TEOM (18% low) and on Whatman QM-A quartz fibre filters (low face velocity, 38% high) are excluded, PM2.5 data agree within 8.1%. For PM10, the agreement is within 6.6% (again excluding the Whatman QM-A quartz fibre filters, 22% high) or 12.1% (all data). For the impactor samples, the data agreed within 6.3% (excluding the ELPI, which was 92% high) and 8.7% for PM2.5 and PM10.
Název v anglickém jazyce
Intercomparison of Methods to Measure the Mass Concentration of the Atmospheric Aerosol during INTERCOMP2000-Influence of Instrumentation and Size Cuts
Popis výsledku anglicky
Within the EUROTRAC-2 subproject AEROSOL, the intensive field campaign INTERCOMP2000 was conducted to compare aerosol samplers and methods to measure various aerosol properties. Here a comparison of mass concentrations measured with different PM2.5 and PM10 samplers as well as cascade impactors is described. Different filter types were used. In general, the PM2.5 and PM10 mass concentrations obtained on filters agree well. The data agree within 18.1% (PM2.5, all data). If data obtained with the TEOM (18% low) and on Whatman QM-A quartz fibre filters (low face velocity, 38% high) are excluded, PM2.5 data agree within 8.1%. For PM10, the agreement is within 6.6% (again excluding the Whatman QM-A quartz fibre filters, 22% high) or 12.1% (all data). For the impactor samples, the data agreed within 6.3% (excluding the ELPI, which was 92% high) and 8.7% for PM2.5 and PM10.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CF - Fyzikální chemie a teoretická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Atmospheric Environment
ISSN
1352-2310
e-ISSN
—
Svazek periodika
38
Číslo periodika v rámci svazku
38
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
6467-6476
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—