Optické sondy a jejich přesnost měření
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F08%3A00309039" target="_blank" >RIV/67985858:_____/08:00309039 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Optical Probes and Their Measurement Precision
Popis výsledku v původním jazyce
The optical probes are commonly used for experimental measurements in gas-liquid multiphase systems. During the measurement, it is evaluated the intensity of the light, which reflects from the tip of the optical fiber placed in the measuring point. Fromthe obtained signals, it is possible to evaluate the bubble residence time, local gas hold-up and it is possible to estimate the size and the velocity of the bubbles. In this study, the signal of the optical probe is compared with the data obtained by direct observation by high-speed camera. It was found that optical probe works well in the case of large and fast moving bubbles. In the case of small and slow bubbles the data measured by optical probe are not usable. The dimensionless criterion for minimal Weber number characterizing the reliability of the probe was derived on the base of motion equation for the bubbles.
Název v anglickém jazyce
Optical Probes and Their Measurement Precision
Popis výsledku anglicky
The optical probes are commonly used for experimental measurements in gas-liquid multiphase systems. During the measurement, it is evaluated the intensity of the light, which reflects from the tip of the optical fiber placed in the measuring point. Fromthe obtained signals, it is possible to evaluate the bubble residence time, local gas hold-up and it is possible to estimate the size and the velocity of the bubbles. In this study, the signal of the optical probe is compared with the data obtained by direct observation by high-speed camera. It was found that optical probe works well in the case of large and fast moving bubbles. In the case of small and slow bubbles the data measured by optical probe are not usable. The dimensionless criterion for minimal Weber number characterizing the reliability of the probe was derived on the base of motion equation for the bubbles.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings
ISBN
978-80-87117-04-0
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
—
Název nakladatele
Institute of Hydrodynamics ASCR, v.v.i
Místo vydání
Prague
Místo konání akce
Holany-Litice
Datum konání akce
3. 6. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—