Measurement Accuracy of a Mono-fiber Optical Probe in a Bubbly Flow
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F10%3A00343074" target="_blank" >RIV/67985858:_____/10:00343074 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement Accuracy of a Mono-fiber Optical Probe in a Bubbly Flow
Popis výsledku v původním jazyce
The measurement accuracy of a mono-fiber optical probe is studied experimentally using isolated bubbles rising freely in a still liquid. The dwell time of the probe tip within the gas phase, which is obtained from both the optical probe signal and high-speed visualization, is compared with the dwell time expected for a non-perturbed bubble. The measurement error results mainly from the intrusive nature of the optical probe, which modifies the behavior of the bubble when it comes into contact with the probe tip. The measured dwell time therefore differs from its ideal value that would be found with an unperturbed bubble. For a wetting liquid, the interaction increases the dwell time if the bubble is pierced near its pole, and shortens it for piercing near the equator. It is shown that the error can be correlated with a modified Weber number, and this correlation is helpful for sensor selection and for uncertainty estimate.
Název v anglickém jazyce
Measurement Accuracy of a Mono-fiber Optical Probe in a Bubbly Flow
Popis výsledku anglicky
The measurement accuracy of a mono-fiber optical probe is studied experimentally using isolated bubbles rising freely in a still liquid. The dwell time of the probe tip within the gas phase, which is obtained from both the optical probe signal and high-speed visualization, is compared with the dwell time expected for a non-perturbed bubble. The measurement error results mainly from the intrusive nature of the optical probe, which modifies the behavior of the bubble when it comes into contact with the probe tip. The measured dwell time therefore differs from its ideal value that would be found with an unperturbed bubble. For a wetting liquid, the interaction increases the dwell time if the bubble is pierced near its pole, and shortens it for piercing near the equator. It is shown that the error can be correlated with a modified Weber number, and this correlation is helpful for sensor selection and for uncertainty estimate.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Multiphase Flow
ISSN
0301-9322
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
16
Strana od-do
—
Kód UT WoS článku
000278693800002
EID výsledku v databázi Scopus
—