The Transitional Regime of Backward-Facing Step Flows
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F11%3A00372521" target="_blank" >RIV/67985858:_____/11:00372521 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Transitional Regime of Backward-Facing Step Flows
Popis výsledku v původním jazyce
The backward-facing step flow is investigated experimentally (electrodiffusion technique) and numerically (CFD software Fluent) at moderate Reynolds numbers achieved in a water channel. The direction sensitive sensors are used to measure the wall shear rate behind the step and detect the near-wall extent of different flow-recirculation regions. 2D numerical simulations provide additional information on the global flow rearrangement caused by the change of operational parameters (channel expansion ratios, inlet flow conditions). At the transitional flow regime, the near-wall flow exhibits an unsteady character with a high sensitivity to external low-frequency perturbations (intrinsic flow instability). The inlet pulsatile forcing is found to affect strongly the overall flow structure behind the step, resulting in the reattachment length reduction and the reverse flow intensification.
Název v anglickém jazyce
The Transitional Regime of Backward-Facing Step Flows
Popis výsledku anglicky
The backward-facing step flow is investigated experimentally (electrodiffusion technique) and numerically (CFD software Fluent) at moderate Reynolds numbers achieved in a water channel. The direction sensitive sensors are used to measure the wall shear rate behind the step and detect the near-wall extent of different flow-recirculation regions. 2D numerical simulations provide additional information on the global flow rearrangement caused by the change of operational parameters (channel expansion ratios, inlet flow conditions). At the transitional flow regime, the near-wall flow exhibits an unsteady character with a high sensitivity to external low-frequency perturbations (intrinsic flow instability). The inlet pulsatile forcing is found to affect strongly the overall flow structure behind the step, resulting in the reattachment length reduction and the reverse flow intensification.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP101%2F11%2F0806" target="_blank" >GAP101/11/0806: Vliv povrchově aktivních látek na proudění ve vícefázových systémech</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings
ISBN
978-80-7372-784-0
ISSN
—
e-ISSN
—
Počet stran výsledku
18
Strana od-do
1022-1039
Název nakladatele
Technical University of Liberec
Místo vydání
Liberec
Místo konání akce
Jičín
Datum konání akce
22. 11. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—