The Transitional Backward-Facing Step Flow in a Water Channel with Variable Expansion Geometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F12%3A00376600" target="_blank" >RIV/67985858:_____/12:00376600 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.expthermflusci.2012.02.006" target="_blank" >http://dx.doi.org/10.1016/j.expthermflusci.2012.02.006</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.expthermflusci.2012.02.006" target="_blank" >10.1016/j.expthermflusci.2012.02.006</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Transitional Backward-Facing Step Flow in a Water Channel with Variable Expansion Geometry
Popis výsledku v původním jazyce
The backward-facing step flow is investigated experimentally and numerically at moderate Reynolds numbers. The different channel expansion ratios (ER = 1.4, 2, 2.5, and 4) and inlet flow conditions (steady and pulsatile) are applied with the aim to analyze the structure and stability of the flow behind the step. The electrodiffusion technique is used to measure the wall shear rate along the experimental water channel. The direction sensitive sensors detect the near-wall extent of different flow-recirculation regions (the primary recirculation, the secondary corner, roof, and bottom eddies). The results of 2D numerical simulations performed in commercial CFD software FLUENT provide additional information on the global flow rearrangement caused by the change of operation parameters.
Název v anglickém jazyce
The Transitional Backward-Facing Step Flow in a Water Channel with Variable Expansion Geometry
Popis výsledku anglicky
The backward-facing step flow is investigated experimentally and numerically at moderate Reynolds numbers. The different channel expansion ratios (ER = 1.4, 2, 2.5, and 4) and inlet flow conditions (steady and pulsatile) are applied with the aim to analyze the structure and stability of the flow behind the step. The electrodiffusion technique is used to measure the wall shear rate along the experimental water channel. The direction sensitive sensors detect the near-wall extent of different flow-recirculation regions (the primary recirculation, the secondary corner, roof, and bottom eddies). The results of 2D numerical simulations performed in commercial CFD software FLUENT provide additional information on the global flow rearrangement caused by the change of operation parameters.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Experimental Thermal and Fluid Science
ISSN
0894-1777
e-ISSN
—
Svazek periodika
40
Číslo periodika v rámci svazku
JUL
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
112-125
Kód UT WoS článku
000304513700013
EID výsledku v databázi Scopus
—