Comparison of electrorheological measurements based on different methods of electric field generation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985874%3A_____%2F14%3A00427857" target="_blank" >RIV/67985874:_____/14:00427857 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/70883521:28610/14:43871801
Výsledek na webu
<a href="http://dx.doi.org/10.3933/ApplRheol-24-42875" target="_blank" >http://dx.doi.org/10.3933/ApplRheol-24-42875</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3933/ApplRheol-24-42875" target="_blank" >10.3933/ApplRheol-24-42875</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of electrorheological measurements based on different methods of electric field generation
Popis výsledku v původním jazyce
Electrorheological measurements represent a key approach in characterizing the efficiency of electrorheological fluids. The rotational rheometers, the Physica MCR 501 (Anton Paar) equipped with an electrorheological cell and the Bohlin Gemini CVOR 150 (Malvern Instruments) modified for electrorheological experiments generate an electric field in two completely different ways. Each of the two generations has a specific influence on electrorheological measurements. The experimental data were obtained andcompared for a suspension of polyaniline powders mixed (10 wt%) in silicone oil. For a concentric-cylinders arrangement, it was shown that the data are fully comparable for both rheometers. However, for a parallel-plate arrangement, the data using the Physica MCR 501 provide higher values in comparison with both the corresponding plate-plate data obtained with the Bohlin Gemini CVOR 150 and with the mutually comparable concentric cylinders data.
Název v anglickém jazyce
Comparison of electrorheological measurements based on different methods of electric field generation
Popis výsledku anglicky
Electrorheological measurements represent a key approach in characterizing the efficiency of electrorheological fluids. The rotational rheometers, the Physica MCR 501 (Anton Paar) equipped with an electrorheological cell and the Bohlin Gemini CVOR 150 (Malvern Instruments) modified for electrorheological experiments generate an electric field in two completely different ways. Each of the two generations has a specific influence on electrorheological measurements. The experimental data were obtained andcompared for a suspension of polyaniline powders mixed (10 wt%) in silicone oil. For a concentric-cylinders arrangement, it was shown that the data are fully comparable for both rheometers. However, for a parallel-plate arrangement, the data using the Physica MCR 501 provide higher values in comparison with both the corresponding plate-plate data obtained with the Bohlin Gemini CVOR 150 and with the mutually comparable concentric cylinders data.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP105%2F11%2F2342" target="_blank" >GAP105/11/2342: Evaluace procesu elektrozvlákňování pomocí elektroreologických měření</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Rheology
ISSN
1430-6395
e-ISSN
—
Svazek periodika
24
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
4
Strana od-do
42875-1-42875-4
Kód UT WoS článku
000342886700005
EID výsledku v databázi Scopus
—