Comparison of electrorheological measurements using different geometries in two commercial rotational rheometers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985874%3A_____%2F17%3A00458816" target="_blank" >RIV/67985874:_____/17:00458816 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.2174/2405465801666161018110438" target="_blank" >http://dx.doi.org/10.2174/2405465801666161018110438</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2174/2405465801666161018110438" target="_blank" >10.2174/2405465801666161018110438</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of electrorheological measurements using different geometries in two commercial rotational rheometers
Popis výsledku v původním jazyce
Background: Efficiency of the individual electrorheological materials is evaluated through their electrorheological characteristics. However, these characteristics are obtained using not only various geometries (plate-plate or concentric cylinders) but also completely different generation of an applied electric field.nnObjective: Responsibility (comparison) of an electrorheological characterization by the individual measurements.nnMethods: This study summarizes and compares the results for one identical material (suspension of polyaniline powders mixed (10 wt%) in silicone oil) using both geometries housed in two commercial rotational rheometers: MCR 501 (Anton Paar Co.) and Gemini CVOR 150 (Malvern Instruments) in which the electric circuit loops are completed by a metal spring wire leaning against a central shaft and through an electrolyte filled in the circumferential gutter, respectively.nnResults: In the case of using the parallel-plate geometry, the data obtained by Physica MCR 501 provides higher values than those obtained by the Gemini CVOR 150. For concentric cylinders the data obtained by both devices are comparable.nnConclusion: For both geometries and devices the functional behaviour of the studied rheological characteristics is in full correspondence.
Název v anglickém jazyce
Comparison of electrorheological measurements using different geometries in two commercial rotational rheometers
Popis výsledku anglicky
Background: Efficiency of the individual electrorheological materials is evaluated through their electrorheological characteristics. However, these characteristics are obtained using not only various geometries (plate-plate or concentric cylinders) but also completely different generation of an applied electric field.nnObjective: Responsibility (comparison) of an electrorheological characterization by the individual measurements.nnMethods: This study summarizes and compares the results for one identical material (suspension of polyaniline powders mixed (10 wt%) in silicone oil) using both geometries housed in two commercial rotational rheometers: MCR 501 (Anton Paar Co.) and Gemini CVOR 150 (Malvern Instruments) in which the electric circuit loops are completed by a metal spring wire leaning against a central shaft and through an electrolyte filled in the circumferential gutter, respectively.nnResults: In the case of using the parallel-plate geometry, the data obtained by Physica MCR 501 provides higher values than those obtained by the Gemini CVOR 150. For concentric cylinders the data obtained by both devices are comparable.nnConclusion: For both geometries and devices the functional behaviour of the studied rheological characteristics is in full correspondence.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Current Smart Materials
ISSN
2405-4658
e-ISSN
—
Svazek periodika
2
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
KR - Korejská republika
Počet stran výsledku
5
Strana od-do
20-24
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—