Poly(luminol) based sensor array for determination of dissolved chlorine in water
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985882%3A_____%2F14%3A00428554" target="_blank" >RIV/67985882:_____/14:00428554 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.snb.2013.10.080" target="_blank" >http://dx.doi.org/10.1016/j.snb.2013.10.080</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.snb.2013.10.080" target="_blank" >10.1016/j.snb.2013.10.080</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Poly(luminol) based sensor array for determination of dissolved chlorine in water
Popis výsledku v původním jazyce
An optical sensor for determination of free chlorine content of drinking water was prepared and tested. The function of the sensor is based on detecting chemiluminescence signal provided by thin immobilized poly(luminol) reagent layer. The poly(luminol)reagent film was prepared by electropolymerization of luminol onto planar indium-tin-oxide (ITO) electrode. Different methods, like electrode potential cyclization (cyclic voltammetry, CV), pulsed potential electrolysis (pulsed amperometry, PA) and potentiostatic electrolysis (constant potential electrolysis, PSE) were employed for preparation of the poly(luminol) layer. The chemoluminescence (chemiluminescence) of the differently prepared films was investigated in the poly(luminol) - hypochlorite - hydrogen peroxide reaction. Highest luminescence signal was obtained by the films prepared with CV. Poly(luminol) layers deposited with pulsed potential showed 80% less luminescence while almost no signal was obtained in case of films made w
Název v anglickém jazyce
Poly(luminol) based sensor array for determination of dissolved chlorine in water
Popis výsledku anglicky
An optical sensor for determination of free chlorine content of drinking water was prepared and tested. The function of the sensor is based on detecting chemiluminescence signal provided by thin immobilized poly(luminol) reagent layer. The poly(luminol)reagent film was prepared by electropolymerization of luminol onto planar indium-tin-oxide (ITO) electrode. Different methods, like electrode potential cyclization (cyclic voltammetry, CV), pulsed potential electrolysis (pulsed amperometry, PA) and potentiostatic electrolysis (constant potential electrolysis, PSE) were employed for preparation of the poly(luminol) layer. The chemoluminescence (chemiluminescence) of the differently prepared films was investigated in the poly(luminol) - hypochlorite - hydrogen peroxide reaction. Highest luminescence signal was obtained by the films prepared with CV. Poly(luminol) layers deposited with pulsed potential showed 80% less luminescence while almost no signal was obtained in case of films made w
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensors and Actuators B - Chemical
ISSN
0925-4005
e-ISSN
—
Svazek periodika
—
Číslo periodika v rámci svazku
192
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
7
Strana od-do
92-98