A frame-supported ultrathin electrospun polymer membrane for transplantation of retinal pigment epithelial cells
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985904%3A_____%2F15%3A00446658" target="_blank" >RIV/67985904:_____/15:00446658 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389013:_____/15:00446658 RIV/00216208:11110/15:10297879 RIV/00216208:11120/15:43910261
Výsledek na webu
<a href="http://dx.doi.org/10.1088/1748-6041/10/4/045022" target="_blank" >http://dx.doi.org/10.1088/1748-6041/10/4/045022</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-6041/10/4/045022" target="_blank" >10.1088/1748-6041/10/4/045022</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A frame-supported ultrathin electrospun polymer membrane for transplantation of retinal pigment epithelial cells
Popis výsledku v původním jazyce
We report on the design and fabrication of a frame-supported nanofibrous membrane for the transplantation of retinal pigment epithelial (RPE) cells, which is a promising therapeutic option for the treatment of degenerative retinal disorders. The membranous cell carrier prepared from 640 nm-thick poly(DL-lactide) fibres uniquely combines high porosity, large pore size and low thickness, to maximize the nutrient supply to the transplanted cells in the subretinal space and thus to enhance the therapeutic effect of the transplantation. The carrier was prepared by electrospinning, which made it easy to embed a 95 μm-thick circular supporting frame 2 mm in diameter. Implantations into enucleated porcine eyes showed that the frame enabled the ultrathin membrane to be handled without irreversible folding, and allowed the membrane to regain its flat shape when inserted into the subretinal space. We further demonstrated that the minimum membrane thickness compatible with the surgical procedure and instrumentation employed here was as low as 4 μm. Primary porcine RPE cells cultivated on the membranes formed a confluent monolayer, expressed RPE-specific differentiation markers and showed transepithelial resistance close to that of the native RPE. Most importantly, the majority of the RPE cells transplanted into the subretinal space remained viable. The ultrathin, highly porous, and surgically convenient cell carrier presented here has the potential to improve the integration and the functionality of transplanted RPE cells.
Název v anglickém jazyce
A frame-supported ultrathin electrospun polymer membrane for transplantation of retinal pigment epithelial cells
Popis výsledku anglicky
We report on the design and fabrication of a frame-supported nanofibrous membrane for the transplantation of retinal pigment epithelial (RPE) cells, which is a promising therapeutic option for the treatment of degenerative retinal disorders. The membranous cell carrier prepared from 640 nm-thick poly(DL-lactide) fibres uniquely combines high porosity, large pore size and low thickness, to maximize the nutrient supply to the transplanted cells in the subretinal space and thus to enhance the therapeutic effect of the transplantation. The carrier was prepared by electrospinning, which made it easy to embed a 95 μm-thick circular supporting frame 2 mm in diameter. Implantations into enucleated porcine eyes showed that the frame enabled the ultrathin membrane to be handled without irreversible folding, and allowed the membrane to regain its flat shape when inserted into the subretinal space. We further demonstrated that the minimum membrane thickness compatible with the surgical procedure and instrumentation employed here was as low as 4 μm. Primary porcine RPE cells cultivated on the membranes formed a confluent monolayer, expressed RPE-specific differentiation markers and showed transepithelial resistance close to that of the native RPE. Most importantly, the majority of the RPE cells transplanted into the subretinal space remained viable. The ultrathin, highly porous, and surgically convenient cell carrier presented here has the potential to improve the integration and the functionality of transplanted RPE cells.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CD - Makromolekulární chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Materials
ISSN
1748-6041
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
15
Strana od-do
"045022_1"-"045022_15"
Kód UT WoS článku
000360215600023
EID výsledku v databázi Scopus
2-s2.0-84982810079