Simple non-invasive analysis of embryonic stem cell-derived cardiomyocytes beating in vitro
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081707%3A_____%2F16%3A00472055" target="_blank" >RIV/68081707:_____/16:00472055 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/16:00064994 RIV/00216224:14310/16:00089517
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.4941776" target="_blank" >http://dx.doi.org/10.1063/1.4941776</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.4941776" target="_blank" >10.1063/1.4941776</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simple non-invasive analysis of embryonic stem cell-derived cardiomyocytes beating in vitro
Popis výsledku v původním jazyce
The analysis of digital video output enables the non-invasive screening of various active biological processes. For the monitoring and computing of the beating parameters of cardiomyocytes in vitro, CB Analyser (cardiomyocyte beating analyser) software was developed. This software is based on image analysis of the video recording of beating cardiomyocytes. CB Analyser was tested using cardiomyocytes derived from mouse embryonic stem cells at different stages of cardiomyogenesis. We observed that during differentiation (from day 18), the beat peak width decreased, which corresponded to the increased speed of an individual pulse. However, the beating frequency did not change. Further, the effects of epinephrine modulating mature cardiomyocyte functions were tested to validate the CB Analyser analysis. In conclusion, data show that CB Analyser is a useful tool for evaluating the functions of both developing and mature cardiomyocytes under various conditions in vitro. (C) 2016 AIP Publishing LLC.
Název v anglickém jazyce
Simple non-invasive analysis of embryonic stem cell-derived cardiomyocytes beating in vitro
Popis výsledku anglicky
The analysis of digital video output enables the non-invasive screening of various active biological processes. For the monitoring and computing of the beating parameters of cardiomyocytes in vitro, CB Analyser (cardiomyocyte beating analyser) software was developed. This software is based on image analysis of the video recording of beating cardiomyocytes. CB Analyser was tested using cardiomyocytes derived from mouse embryonic stem cells at different stages of cardiomyogenesis. We observed that during differentiation (from day 18), the beat peak width decreased, which corresponded to the increased speed of an individual pulse. However, the beating frequency did not change. Further, the effects of epinephrine modulating mature cardiomyocyte functions were tested to validate the CB Analyser analysis. In conclusion, data show that CB Analyser is a useful tool for evaluating the functions of both developing and mature cardiomyocytes under various conditions in vitro. (C) 2016 AIP Publishing LLC.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Review of Scientific Instruments
ISSN
0034-6748
e-ISSN
—
Svazek periodika
87
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
000371740900257
EID výsledku v databázi Scopus
—