Rapid capillary coating by epoxy-poly-(dimethylacrylamide): Performance in capillary zone electrophoresis of protein and polystyrene carboxylate.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F01%3A25010011" target="_blank" >RIV/68081715:_____/01:25010011 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Rapid capillary coating by epoxy-poly-(dimethylacrylamide): Performance in capillary zone electrophoresis of protein and polystyrene carboxylate.
Popis výsledku v původním jazyce
A fast and simple method for the internal coating of capillaries in capillary zone electrophoresis (CZE) is that with epoxy-poly(dimethylacrylamide) (EPDMA), Duration of coating by that method is 30 min, compared with that of 24 h when using uncross-linked polyacrylamide (PA) under otherwise identical conditions. Under the conditions used for the CZE of proteins (pH 9.0, 2% polyethylene glycol), the capillary coating with EPDMA is stable for at least 50 consecutive runs as judged by the constancy of lowelectroosmotic flow, equalling the stability of coating achieved by PA. Protein mobilities and protein peak asymmetry (suggestive of reversible interaction with the capillary wall) are also found to be the same in EPDMA and PA coated capillaries. Differences between EPDMA and PA coating also exist. The former is unstable upon lowering the ionic strength of the buffer to 0.003, upon the addition of sodium dodecyl sulfate (SDS) to the buffer and in application to the hydrophobic analyte,
Název v anglickém jazyce
Rapid capillary coating by epoxy-poly-(dimethylacrylamide): Performance in capillary zone electrophoresis of protein and polystyrene carboxylate.
Popis výsledku anglicky
A fast and simple method for the internal coating of capillaries in capillary zone electrophoresis (CZE) is that with epoxy-poly(dimethylacrylamide) (EPDMA), Duration of coating by that method is 30 min, compared with that of 24 h when using uncross-linked polyacrylamide (PA) under otherwise identical conditions. Under the conditions used for the CZE of proteins (pH 9.0, 2% polyethylene glycol), the capillary coating with EPDMA is stable for at least 50 consecutive runs as judged by the constancy of lowelectroosmotic flow, equalling the stability of coating achieved by PA. Protein mobilities and protein peak asymmetry (suggestive of reversible interaction with the capillary wall) are also found to be the same in EPDMA and PA coated capillaries. Differences between EPDMA and PA coating also exist. The former is unstable upon lowering the ionic strength of the buffer to 0.003, upon the addition of sodium dodecyl sulfate (SDS) to the buffer and in application to the hydrophobic analyte,
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2001
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
4
Strana od-do
656-659
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—