Dvourozměrná gelová izoelektrická fokusace
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F05%3A00021374" target="_blank" >RIV/68081715:_____/05:00021374 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Two-dimensional gel isoelectric focusing
Popis výsledku v původním jazyce
The unique properties of IEF, focusing and resolution power, were enhanced by using the same technique twice in two directions of the same gel. Two forms of beta-lactoglobulin (pI values 5.14 and 5.31) nonseparated in the first IEF were successfully separated in the second dimension at relatively low voltage (330 V) with the resolution power comparable to the high-resolusion gels requiring the high voltage during the run and long separation time. Glucose oxidase loaded as diluted solution into ten positions across the gel was finally focused into a single band during 2-D gel IEF. Since the first and second IEF are carried out on the same gel, no losses and contamination of analyte occur. The suggested method can be used for separation/fractionation ofcomplex biological mixtures followed by e.g. mass spectrometry analysis.
Název v anglickém jazyce
Two-dimensional gel isoelectric focusing
Popis výsledku anglicky
The unique properties of IEF, focusing and resolution power, were enhanced by using the same technique twice in two directions of the same gel. Two forms of beta-lactoglobulin (pI values 5.14 and 5.31) nonseparated in the first IEF were successfully separated in the second dimension at relatively low voltage (330 V) with the resolution power comparable to the high-resolusion gels requiring the high voltage during the run and long separation time. Glucose oxidase loaded as diluted solution into ten positions across the gel was finally focused into a single band during 2-D gel IEF. Since the first and second IEF are carried out on the same gel, no losses and contamination of analyte occur. The suggested method can be used for separation/fractionation ofcomplex biological mixtures followed by e.g. mass spectrometry analysis.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
18
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
3586-3591
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—