Filtration microcartridge and capillary isoelectric focusing for the analysis low number of microorganisms in real samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F12%3A00386009" target="_blank" >RIV/68081715:_____/12:00386009 - isvavai.cz</a>
Výsledek na webu
<a href="http://hdl.handle.net/11104/0215232" target="_blank" >http://hdl.handle.net/11104/0215232</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Filtration microcartridge and capillary isoelectric focusing for the analysis low number of microorganisms in real samples
Popis výsledku v původním jazyce
At present, detection and identification of microorganisms in real biological samples needs very sensitive methods for correct diagnosis and therapy in medical practice, biotechnology, agriculture, food safety and quality etc. Accordingly, it is essential to develop new cheap techniques for pathogen identification, particularly for pathogen in complex biological samples. Pre-concentration, separation, and sensitive detection of whole cells in one step are great potential and advantage for detection of pathogens in low concentration. Combination of filtration microcartridge and capillary isoelectric focusing was developed for pre-concentration and pre-separation of microorganisms from real suspensions and the possibility its application to real sampleswas verified.
Název v anglickém jazyce
Filtration microcartridge and capillary isoelectric focusing for the analysis low number of microorganisms in real samples
Popis výsledku anglicky
At present, detection and identification of microorganisms in real biological samples needs very sensitive methods for correct diagnosis and therapy in medical practice, biotechnology, agriculture, food safety and quality etc. Accordingly, it is essential to develop new cheap techniques for pathogen identification, particularly for pathogen in complex biological samples. Pre-concentration, separation, and sensitive detection of whole cells in one step are great potential and advantage for detection of pathogens in low concentration. Combination of filtration microcartridge and capillary isoelectric focusing was developed for pre-concentration and pre-separation of microorganisms from real suspensions and the possibility its application to real sampleswas verified.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2012. 9th International Interdisciplinary Meeting on Bioanalysis
ISBN
978-80-904959-1-3
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
225-227
Název nakladatele
Ústav analytické chemie AV ČR, v. v. i
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
1. 11. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—