Capillary isotachophoresis with ESI-MS detection: Methodology for highly sensitive analysis of ibuprofen and diclofenac in waters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F16%3A00456038" target="_blank" >RIV/68081715:_____/16:00456038 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.aca.2015.11.040" target="_blank" >http://dx.doi.org/10.1016/j.aca.2015.11.040</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2015.11.040" target="_blank" >10.1016/j.aca.2015.11.040</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capillary isotachophoresis with ESI-MS detection: Methodology for highly sensitive analysis of ibuprofen and diclofenac in waters
Popis výsledku v původním jazyce
The possibilities of reaching higher sensitivity in capillary electrophoretic analyses of complex samples with ESI-MS detection were investigated on the example of analysis of diclofenac and ibuprofen in waters. The applied separation approach is based on application of isotachophoresis that ensures permanent stacking of analytes until they reach the detector. Investigation of the possibilities of MS detector optimization have shown that optimization of fragmentor voltage and working in the SIM mode with collection of data for multiple fragments both increases the method specificity and approx. doubles its sensitivity.
Název v anglickém jazyce
Capillary isotachophoresis with ESI-MS detection: Methodology for highly sensitive analysis of ibuprofen and diclofenac in waters
Popis výsledku anglicky
The possibilities of reaching higher sensitivity in capillary electrophoretic analyses of complex samples with ESI-MS detection were investigated on the example of analysis of diclofenac and ibuprofen in waters. The applied separation approach is based on application of isotachophoresis that ensures permanent stacking of analytes until they reach the detector. Investigation of the possibilities of MS detector optimization have shown that optimization of fragmentor voltage and working in the SIM mode with collection of data for multiple fragments both increases the method specificity and approx. doubles its sensitivity.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA13-05762S" target="_blank" >GA13-05762S: Teorie, metodologie a vývoj progresivních chemických metod pro analýzu stopových složek a složitých vzorků kapilární elektroforézou.</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
907
Číslo periodika v rámci svazku
FEB
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
6
Strana od-do
1-6
Kód UT WoS článku
000368422900001
EID výsledku v databázi Scopus
—