A Validatation of non-invasive method for diagnostic of cystic fibrosis based on ion ratios determined by CE-C4D
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F18%3A00498535" target="_blank" >RIV/68081715:_____/18:00498535 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.ce-ce.org/user_uploads/program/CECE%202018%20Proceedings_WOS.pdf" target="_blank" >http://www.ce-ce.org/user_uploads/program/CECE%202018%20Proceedings_WOS.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Validatation of non-invasive method for diagnostic of cystic fibrosis based on ion ratios determined by CE-C4D
Popis výsledku v původním jazyce
A validation of novel approach for diagnosis of cystic fibrosis (CF) is presented. The method is very simple and fast, since for collection of samples, only wiping of the skin of forearm is needed. The collected sample is analyzed by capillary electrophoresis with contactless conductometric detection (CE-C4D). Ion ratios are determined as ratios of peak area of chloride anion and peak areas of selected cations. It is possible to distinguish between cystic fibrosis patients and healthy individuals when ion ratio is applied as diagnostic factor. In here, we present analytical parameters of developed method (limits of detection, limits of quantification, repeatability of migration times, repeatability of peak areas) and ROC curve, which reveals high sensitivity and specificity of the developed method.
Název v anglickém jazyce
A Validatation of non-invasive method for diagnostic of cystic fibrosis based on ion ratios determined by CE-C4D
Popis výsledku anglicky
A validation of novel approach for diagnosis of cystic fibrosis (CF) is presented. The method is very simple and fast, since for collection of samples, only wiping of the skin of forearm is needed. The collected sample is analyzed by capillary electrophoresis with contactless conductometric detection (CE-C4D). Ion ratios are determined as ratios of peak area of chloride anion and peak areas of selected cations. It is possible to distinguish between cystic fibrosis patients and healthy individuals when ion ratio is applied as diagnostic factor. In here, we present analytical parameters of developed method (limits of detection, limits of quantification, repeatability of migration times, repeatability of peak areas) and ROC curve, which reveals high sensitivity and specificity of the developed method.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2018. 15th International Interdisciplinary Meeting on Bioanalysis
ISBN
978-80-904959-5-1
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
126-131
Název nakladatele
Ústav analytické chemie AV ČR, v. v. i.
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
15. 10. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—