Capillary electrophoresis with preparative isoelectric focusing preconcentration for sensitive determination of amphotericin B in human blood serum
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F19%3A00501010" target="_blank" >RIV/68081715:_____/19:00501010 - isvavai.cz</a>
Výsledek na webu
<a href="http://hdl.handle.net/11104/0293037" target="_blank" >http://hdl.handle.net/11104/0293037</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2018.12.010" target="_blank" >10.1016/j.aca.2018.12.010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capillary electrophoresis with preparative isoelectric focusing preconcentration for sensitive determination of amphotericin B in human blood serum
Popis výsledku v původním jazyce
Amphotericin B (AmB) is still, despite its severe nephrotoxicity, the first-line agent in the management of serious systemic fungal infections. A sensitive and reliable method is therefore required to control AmB concentration in body fluids of a patient. This study demonstrates the potential of the off-line combination of preparative isoelectric focusing (IEF) with capillary isoelectric focusing (CIEF) or capillary zone electrophoresis (CZE) in the determination of AmB in human blood serum. The required value of the isoelectric point of AmB was determined to be 6.1 using the CIEF technique. Preparative IEF served as a pre-separation and concentration technique. The pH gradient was traced by colored low molecular pI markers. The collected fraction with AmB was easily processed and then analyzed by CIEF and CZE. Tens of picograms of AmB in human blood serum sample can be determined by a combination of preparative IEF with CZE. The method was linear in the AmB concentration range of 0.3e600 ngmL 1. The recovery ranged from 93% to 98%.
Název v anglickém jazyce
Capillary electrophoresis with preparative isoelectric focusing preconcentration for sensitive determination of amphotericin B in human blood serum
Popis výsledku anglicky
Amphotericin B (AmB) is still, despite its severe nephrotoxicity, the first-line agent in the management of serious systemic fungal infections. A sensitive and reliable method is therefore required to control AmB concentration in body fluids of a patient. This study demonstrates the potential of the off-line combination of preparative isoelectric focusing (IEF) with capillary isoelectric focusing (CIEF) or capillary zone electrophoresis (CZE) in the determination of AmB in human blood serum. The required value of the isoelectric point of AmB was determined to be 6.1 using the CIEF technique. Preparative IEF served as a pre-separation and concentration technique. The pH gradient was traced by colored low molecular pI markers. The collected fraction with AmB was easily processed and then analyzed by CIEF and CZE. Tens of picograms of AmB in human blood serum sample can be determined by a combination of preparative IEF with CZE. The method was linear in the AmB concentration range of 0.3e600 ngmL 1. The recovery ranged from 93% to 98%.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytica Chimica Acta
ISSN
0003-2670
e-ISSN
—
Svazek periodika
1053
Číslo periodika v rámci svazku
APR
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
162-168
Kód UT WoS článku
000457201600018
EID výsledku v databázi Scopus
2-s2.0-85058795138