Capillary electrophoresis as a sample separation step to mass spectrometry analysis: A primer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F23%3A00572002" target="_blank" >RIV/68081715:_____/23:00572002 - isvavai.cz</a>
Výsledek na webu
<a href="https://hdl.handle.net/11104/0342843" target="_blank" >https://hdl.handle.net/11104/0342843</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.trac.2023.117093" target="_blank" >10.1016/j.trac.2023.117093</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capillary electrophoresis as a sample separation step to mass spectrometry analysis: A primer
Popis výsledku v původním jazyce
Capillary electrophoresis (CE) is a separation technique that offers high resolution, great sensitivity, and short processing times. Mass spectrometry (MS) accurately characterizes ionized species based on mass and fragmentation patterns that identify analytes by their mass to charge ratio. Powerful analytical systems are enabled by hyphenating CE with MS. Introducing a sample separated into individual zones minimizes ion suppression and significantly enhances the capacities of MS. This review article is intended as an introduction to scientists and professionals who are already familiar with electrophoresis and are interested in learning about the analytical potential of CE-MS systems. Working principles and basic instrumentation, including the CE-MS interfaces, are included as the robust and sensitive interfaces are crucial to the acceptance of CE-MS systems in the (bio)analytical practice. A discussion of recent reports on CE-MS systems provides an overview of the latest advances, and the conclusions speculate on future developments.
Název v anglickém jazyce
Capillary electrophoresis as a sample separation step to mass spectrometry analysis: A primer
Popis výsledku anglicky
Capillary electrophoresis (CE) is a separation technique that offers high resolution, great sensitivity, and short processing times. Mass spectrometry (MS) accurately characterizes ionized species based on mass and fragmentation patterns that identify analytes by their mass to charge ratio. Powerful analytical systems are enabled by hyphenating CE with MS. Introducing a sample separated into individual zones minimizes ion suppression and significantly enhances the capacities of MS. This review article is intended as an introduction to scientists and professionals who are already familiar with electrophoresis and are interested in learning about the analytical potential of CE-MS systems. Working principles and basic instrumentation, including the CE-MS interfaces, are included as the robust and sensitive interfaces are crucial to the acceptance of CE-MS systems in the (bio)analytical practice. A discussion of recent reports on CE-MS systems provides an overview of the latest advances, and the conclusions speculate on future developments.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
TrAC-Trends in Analytical Chemistry
ISSN
0165-9936
e-ISSN
1879-3142
Svazek periodika
164
Číslo periodika v rámci svazku
JUL
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
14
Strana od-do
117093
Kód UT WoS článku
001001800400001
EID výsledku v databázi Scopus
2-s2.0-85159558454