Electroextraction of Large Volume Samples Using Paper Points Coupled With Hollow Fiber Membranes: Study of Parameters and Strategies to Enhance Analytical Performance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F24%3A00601035" target="_blank" >RIV/68081715:_____/24:00601035 - isvavai.cz</a>
Výsledek na webu
<a href="https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/epdf/10.1002/elps.202400102" target="_blank" >https://analyticalsciencejournals.onlinelibrary.wiley.com/doi/epdf/10.1002/elps.202400102</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/elps.202400102" target="_blank" >10.1002/elps.202400102</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electroextraction of Large Volume Samples Using Paper Points Coupled With Hollow Fiber Membranes: Study of Parameters and Strategies to Enhance Analytical Performance
Popis výsledku v původním jazyce
Electroextraction (EE) encompasses a range of sample preparation methods whose effectiveness, selectivity, and efficiency are significantly influenced by the physical-chemical characteristics of analytes, samples, and instrumental conditions. This article explores, for the first time, various strategies aimed at enhancing the extraction efficiency of a recent approach of EE utilizing a paper point (PP) combined with a hollow fiber (HF) (abbreviated as PP-HF-EE) to extract various cationic and anionic model compounds from water samples. The study also explores, experimentally, the impact of agitation, organic filter composition, PP diameter, and PP brand on extraction performance, and proves that all these factors are quite important, especially when digital image analysis is utilized for determination. Furthermore, this work demonstrates the ease and feasibility of simultaneously extracting cations and anions using PP-HF-EE and proposes a straightforward method to enhance analyte concentration on the vertex of the PP through a base-to-vertex focusing. Lastly, it is demonstrated, using capillary electrophoresis coupled to a UV-Vis detector, that for PP-HF-EE, the extraction efficiency and pre-concentration factor are less dependent on other parameters when multiple PPs per sample are utilized, with signal enhancement values of up to 111 and 339 for nortriptyline and haloperidol, respectively. All the findings and strategies presented herein constitute significant contributions that can facilitate future research in method development, particularly in the utilization of PP-HF-EE and similar EE approaches.
Název v anglickém jazyce
Electroextraction of Large Volume Samples Using Paper Points Coupled With Hollow Fiber Membranes: Study of Parameters and Strategies to Enhance Analytical Performance
Popis výsledku anglicky
Electroextraction (EE) encompasses a range of sample preparation methods whose effectiveness, selectivity, and efficiency are significantly influenced by the physical-chemical characteristics of analytes, samples, and instrumental conditions. This article explores, for the first time, various strategies aimed at enhancing the extraction efficiency of a recent approach of EE utilizing a paper point (PP) combined with a hollow fiber (HF) (abbreviated as PP-HF-EE) to extract various cationic and anionic model compounds from water samples. The study also explores, experimentally, the impact of agitation, organic filter composition, PP diameter, and PP brand on extraction performance, and proves that all these factors are quite important, especially when digital image analysis is utilized for determination. Furthermore, this work demonstrates the ease and feasibility of simultaneously extracting cations and anions using PP-HF-EE and proposes a straightforward method to enhance analyte concentration on the vertex of the PP through a base-to-vertex focusing. Lastly, it is demonstrated, using capillary electrophoresis coupled to a UV-Vis detector, that for PP-HF-EE, the extraction efficiency and pre-concentration factor are less dependent on other parameters when multiple PPs per sample are utilized, with signal enhancement values of up to 111 and 339 for nortriptyline and haloperidol, respectively. All the findings and strategies presented herein constitute significant contributions that can facilitate future research in method development, particularly in the utilization of PP-HF-EE and similar EE approaches.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
1522-2683
Svazek periodika
46
Číslo periodika v rámci svazku
9-10
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
571-581
Kód UT WoS článku
001344208600001
EID výsledku v databázi Scopus
2-s2.0-85207863602