The fracture behaviour of hybrid glass matrix composite before and after thermal ageing and/or thermal shock cycling in air has been analysed. Chevron notch technique was applied for fracture toughness determination. The KIc values were in the range 2.6-6.4 MPam 1/2 for the as received material and they were significantly reduced by thermal loading. The KIc values dropped to 0.4 MPam 1/2 for ageing at 700 C for 24 h due to fibre oxidation and porosity formation in the matrix as a result of softening ofthe glass. The KIc values decreased to 1.3 MPam 1/2 for the 24 thermal shock cycles from 500C and/or to 1.1 MPam 1/2 for 50 cycles from 600C. The damage in the samples due to thermal shock cycling was explained by fibre oxidation and porosity formation,as in case of thermal ageing, and, in addition, by superposed residual thermal stresses in the matrix produced by repeated thermal shocks
Název v anglickém jazyce
Fracture resistance degradation of hybrid glass matrix composite
Popis výsledku anglicky
The fracture behaviour of hybrid glass matrix composite before and after thermal ageing and/or thermal shock cycling in air has been analysed. Chevron notch technique was applied for fracture toughness determination. The KIc values were in the range 2.6-6.4 MPam 1/2 for the as received material and they were significantly reduced by thermal loading. The KIc values dropped to 0.4 MPam 1/2 for ageing at 700 C for 24 h due to fibre oxidation and porosity formation in the matrix as a result of softening ofthe glass. The KIc values decreased to 1.3 MPam 1/2 for the 24 thermal shock cycles from 500C and/or to 1.1 MPam 1/2 for 50 cycles from 600C. The damage in the samples due to thermal shock cycling was explained by fibre oxidation and porosity formation,as in case of thermal ageing, and, in addition, by superposed residual thermal stresses in the matrix produced by repeated thermal shocks
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JH - Keramika, žáruvzdorné materiály a skla
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
European Conference of Fracture. Advanced Fracture Mechanics for Life and Safety Asessments /15./
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
1-2
Název nakladatele
Royal Institute of Technology (KTH)
Místo vydání
Stockholm
Místo konání akce
Stockholm
Datum konání akce
11. 8. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—