Popis výsledku v původním jazyce
Environmental scanning electron microscope operates with the gaseous environment in the specimen chamber. This environment causes specific conditions for the detection of signal electrons. Classical Everhart-Thornley detector cannot be exploited for thedetection of secondary electrons because of the impossibility to use high enough electric field in a gaseous environment to add sufficient energy to secondary electrons for efficient scintillation. Ionization detector is therefore used for the detectionof signal electrons in environmental SEM most frequently. At this detector a plate electrode with positive potential is positioned above the specimen, which lays on a grounded specimen holder. At operation signal electrons from the specimen are accelerated in electrical field to the positive electrode and are amplified in the process of impact ionisation in a gaseous environment. The positive electrode of the ionisation detects products of ionisation collisions caused by secondary, backs
Název v anglickém jazyce
Usage of Segmental Ionization Detector in Environmental Conditions.
Popis výsledku anglicky
Environmental scanning electron microscope operates with the gaseous environment in the specimen chamber. This environment causes specific conditions for the detection of signal electrons. Classical Everhart-Thornley detector cannot be exploited for thedetection of secondary electrons because of the impossibility to use high enough electric field in a gaseous environment to add sufficient energy to secondary electrons for efficient scintillation. Ionization detector is therefore used for the detectionof signal electrons in environmental SEM most frequently. At this detector a plate electrode with positive potential is positioned above the specimen, which lays on a grounded specimen holder. At operation signal electrons from the specimen are accelerated in electrical field to the positive electrode and are amplified in the process of impact ionisation in a gaseous environment. The positive electrode of the ionisation detects products of ionisation collisions caused by secondary, backs
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F01%2F1271" target="_blank" >GA102/01/1271: Studium detekčních metod a systémů v hraničních podmínkách environmentální rastrovací elektronové mikroskopie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Microscopy and Microanalysis
ISSN
1431-9276
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
Sup. 3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
2
Strana od-do
142-143