Determination of confidence regions of model parameters in mono- and biexponential fitting of relaxation curves.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F03%3A12030087" target="_blank" >RIV/68081731:_____/03:12030087 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of confidence regions of model parameters in mono- and biexponential fitting of relaxation curves.
Popis výsledku v původním jazyce
Various MRI and MRS data sets acquired by relaxation-sensitive measurements were analyzed with the aim to assess the relaxation parameters. Considerable sensitivity of these parameters to the setup of the algorithm used to minimize the quadratic error ofmono- or biexponential models was often found. Bad conditioning was identified as the principal cause, rather than the minimizing algorithm or noise alone. Interpretation of mode parameters should take the inherent uncertainty into account. Simulated and real data were used to study the shape and extent of the confidence regions including those model parameter sets that are consistent with the data measured.
Název v anglickém jazyce
Determination of confidence regions of model parameters in mono- and biexponential fitting of relaxation curves.
Popis výsledku anglicky
Various MRI and MRS data sets acquired by relaxation-sensitive measurements were analyzed with the aim to assess the relaxation parameters. Considerable sensitivity of these parameters to the setup of the algorithm used to minimize the quadratic error ofmono- or biexponential models was often found. Bad conditioning was identified as the principal cause, rather than the minimizing algorithm or noise alone. Interpretation of mode parameters should take the inherent uncertainty into account. Simulated and real data were used to study the shape and extent of the confidence regions including those model parameter sets that are consistent with the data measured.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA202%2F02%2F1493" target="_blank" >GA202/02/1493: Rozvoj modelů a výpočetních metod pro biomedicínské aplikace nukleární magnetické rezonance</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Sociaty for Magnetic Resonance in Medicine - 11th Scientific Meeting and Exhibition.
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
1102
Název nakladatele
ISMRM
Místo vydání
Toronto
Místo konání akce
Toronto [CA]
Datum konání akce
10. 7. 2003
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—