Vliv kvality jodových kyvet na stabilitu a absolutní posuv kmitočtu laserových etalonů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F08%3A00314951" target="_blank" >RIV/68081731:_____/08:00314951 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Iodine Cell Quality onto the Stability and Absolute Frequency Shifts of Laser Etalons
Popis výsledku v původním jazyce
Frequency doubled Nd:YAG lasers are often the option with stabilization to the saturated absorption in molecular iodine featuring good signal-to-noise ratio at the 532 nm. We present results of measurement of purity of sets of iodine cells made at our institute. The purity was tested by improved method based on measurement of induced fluorescence and evaluation by the Stern-Volmer formula. Frequency-doubled Nd:YAG lasers stabilized with these cells were compared to evaluate their frequency shifts. The absolute frequencies of selected iodine hyperfine transitions were measured in direct laser frequency comparison with the reproducibility well below the kHz level. The results indicating the iodine cell purity are presented with relation to the absolute frequency shifts. This not only highlights the influence of iodine cell quality onto the stability and absolute frequency of lasers etalons but also shows the way towards improvements of the iodine cell manufacturing technology.
Název v anglickém jazyce
Influence of Iodine Cell Quality onto the Stability and Absolute Frequency Shifts of Laser Etalons
Popis výsledku anglicky
Frequency doubled Nd:YAG lasers are often the option with stabilization to the saturated absorption in molecular iodine featuring good signal-to-noise ratio at the 532 nm. We present results of measurement of purity of sets of iodine cells made at our institute. The purity was tested by improved method based on measurement of induced fluorescence and evaluation by the Stern-Volmer formula. Frequency-doubled Nd:YAG lasers stabilized with these cells were compared to evaluate their frequency shifts. The absolute frequencies of selected iodine hyperfine transitions were measured in direct laser frequency comparison with the reproducibility well below the kHz level. The results indicating the iodine cell purity are presented with relation to the absolute frequency shifts. This not only highlights the influence of iodine cell quality onto the stability and absolute frequency of lasers etalons but also shows the way towards improvements of the iodine cell manufacturing technology.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Ninth International Symposium on Laser Metrology. (Proceedings of SPIE Vol. 7155)
ISBN
978-0-8194-7398-1
ISSN
—
e-ISSN
—
Počet stran výsledku
9
Strana od-do
—
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Singapore
Datum konání akce
30. 6. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—