Magnetic susceptibility measurement using 2D magnetic resonance imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F11%3A00366067" target="_blank" >RIV/68081731:_____/11:00366067 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/11:PU93286
Výsledek na webu
<a href="http://dx.doi.org/10.1088/0957-0233/22/10/105702" target="_blank" >http://dx.doi.org/10.1088/0957-0233/22/10/105702</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0957-0233/22/10/105702" target="_blank" >10.1088/0957-0233/22/10/105702</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Magnetic susceptibility measurement using 2D magnetic resonance imaging
Popis výsledku v původním jazyce
The authors describe a nuclear magnetic resonance (NMR) method for measuring the magnetic susceptibility of bar-shaped samples that have an arbitrary cross-section and do not produce an MR signal. The method is based on the measurement of the 2D map of the reaction field in the vicinity of a non-ferromagnetic sample and on the calculation of magnetic susceptibility from a known reaction field. The verification of the technique was realized via modelling the measured configuration in the ANSYS program bymeans of the finite element method and through an experimental measurement of MR-compatible and MR-incompatible materials carried out on a tomograph. A great advantage of the proposed susceptibility evaluation method consists in the use of only standardcommercially used devices without the need of any special sequences.
Název v anglickém jazyce
Magnetic susceptibility measurement using 2D magnetic resonance imaging
Popis výsledku anglicky
The authors describe a nuclear magnetic resonance (NMR) method for measuring the magnetic susceptibility of bar-shaped samples that have an arbitrary cross-section and do not produce an MR signal. The method is based on the measurement of the 2D map of the reaction field in the vicinity of a non-ferromagnetic sample and on the calculation of magnetic susceptibility from a known reaction field. The verification of the technique was realized via modelling the measured configuration in the ANSYS program bymeans of the finite element method and through an experimental measurement of MR-compatible and MR-incompatible materials carried out on a tomograph. A great advantage of the proposed susceptibility evaluation method consists in the use of only standardcommercially used devices without the need of any special sequences.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Measurement Science and Technology
ISSN
0957-0233
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
"105702:1"-"8"
Kód UT WoS článku
000294819500045