Imaging of early conifer embryogenic tissues with the environmental scanning electron microscope
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F12%3A00385176" target="_blank" >RIV/68081731:_____/12:00385176 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s10535-012-0062-x" target="_blank" >http://dx.doi.org/10.1007/s10535-012-0062-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10535-012-0062-x" target="_blank" >10.1007/s10535-012-0062-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Imaging of early conifer embryogenic tissues with the environmental scanning electron microscope
Popis výsledku v původním jazyce
This article describes the usage of non-commercial environmental scanning electron microscope (ESEM) for the visualization of plant extracellular matrix in Abies alba and Abies numidica. Non sputter-coated samples free of using the common fixation technique observed at the relatively low humidity of the air environment with the pressure 550 Pa and the low temperature of the sample from -18 to -22A degrees C give surprisingly very good results that show the natural structure of the tissues. This seems tobe generally applicable. Moreover, a specially designed ionization detector of secondary electrons and a YAG:Ce3+ detector of backscattered electrons were used for better comparison.
Název v anglickém jazyce
Imaging of early conifer embryogenic tissues with the environmental scanning electron microscope
Popis výsledku anglicky
This article describes the usage of non-commercial environmental scanning electron microscope (ESEM) for the visualization of plant extracellular matrix in Abies alba and Abies numidica. Non sputter-coated samples free of using the common fixation technique observed at the relatively low humidity of the air environment with the pressure 550 Pa and the low temperature of the sample from -18 to -22A degrees C give surprisingly very good results that show the natural structure of the tissues. This seems tobe generally applicable. Moreover, a specially designed ionization detector of secondary electrons and a YAG:Ce3+ detector of backscattered electrons were used for better comparison.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F10%2F1410" target="_blank" >GAP102/10/1410: Studium vlivu magnetického a elektrostatického pole na zesílení signálu sekundárních elektronů detekovaných novým detektorem pro VP-SEM.</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biologia Plantarum
ISSN
0006-3134
e-ISSN
—
Svazek periodika
56
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
595-598
Kód UT WoS článku
000303062400028
EID výsledku v databázi Scopus
—