Electrochemical Performances of Diamond Like Carbon Films for Pb(II) Detection in Tap Water Using Differential Pulse Anodic Stripping Voltammetry Technique
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F13%3A00422028" target="_blank" >RIV/68081731:_____/13:00422028 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1166/sl.2013.2843" target="_blank" >http://dx.doi.org/10.1166/sl.2013.2843</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1166/sl.2013.2843" target="_blank" >10.1166/sl.2013.2843</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical Performances of Diamond Like Carbon Films for Pb(II) Detection in Tap Water Using Differential Pulse Anodic Stripping Voltammetry Technique
Popis výsledku v původním jazyce
In this study, the DLC (Diamond Like Carbon) electrode deposited on a planar screen-printed electrochemical cell, was used as working electrode for electrochemical detection in trace amounts of heavy metals, especially lead, using Differential Pulse Anodic Stripping voltammetry (DPASV) technique. Pb+2 were detected at a potential and time deposit equal to 1.5 V and 5 s respectively and scan rate of 0.07 V/s. The results obtained show a very high sensitivity of the DLC electrodes towards Pb. Through DPASV technique, tap water of Lyon city (France) could be analysed, using the method of standard additions with a lead solution 1 mg/L. the obtained concentration of lead was 0.850.05 ?g/L, confirmed using ICP-MS, less than the prescribed value by French standard (10 ?g/L of Pb in drinking water).
Název v anglickém jazyce
Electrochemical Performances of Diamond Like Carbon Films for Pb(II) Detection in Tap Water Using Differential Pulse Anodic Stripping Voltammetry Technique
Popis výsledku anglicky
In this study, the DLC (Diamond Like Carbon) electrode deposited on a planar screen-printed electrochemical cell, was used as working electrode for electrochemical detection in trace amounts of heavy metals, especially lead, using Differential Pulse Anodic Stripping voltammetry (DPASV) technique. Pb+2 were detected at a potential and time deposit equal to 1.5 V and 5 s respectively and scan rate of 0.07 V/s. The results obtained show a very high sensitivity of the DLC electrodes towards Pb. Through DPASV technique, tap water of Lyon city (France) could be analysed, using the method of standard additions with a lead solution 1 mg/L. the obtained concentration of lead was 0.850.05 ?g/L, confirmed using ICP-MS, less than the prescribed value by French standard (10 ?g/L of Pb in drinking water).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Sensor Letters
ISSN
1546-198X
e-ISSN
—
Svazek periodika
11
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
1524-1529
Kód UT WoS článku
000330418100022
EID výsledku v databázi Scopus
—