Performance of SEM Scintillation Detector Evaluated by Modulation Transfer Function and Detective Quantum Efficiency Function
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F14%3A00430357" target="_blank" >RIV/68081731:_____/14:00430357 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1002/sca.21130" target="_blank" >http://dx.doi.org/10.1002/sca.21130</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/sca.21130" target="_blank" >10.1002/sca.21130</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Performance of SEM Scintillation Detector Evaluated by Modulation Transfer Function and Detective Quantum Efficiency Function
Popis výsledku v původním jazyce
In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector?s influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for theSEM detector are described. In this technique, the time modulated ebeam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart?Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type o
Název v anglickém jazyce
Performance of SEM Scintillation Detector Evaluated by Modulation Transfer Function and Detective Quantum Efficiency Function
Popis výsledku anglicky
In the paper, the SEM detector is evaluated by the modulation transfer function (MTF) which expresses the detector?s influence on the SEM image contrast. This is a novel approach, since the MTF was used previously to describe only the area imaging detectors, or whole imaging systems. The measurement technique and calculation of the MTF for the SEM detector are presented. In addition, the measurement and calculation of the detective quantum efficiency (DQE) as a function of the spatial frequency for theSEM detector are described. In this technique, the time modulated ebeam is used in order to create well-defined input signal for the detector. The MTF and DQE measurements are demonstrated on the Everhart?Thornley scintillation detector. This detector was alternated using the YAG:Ce, YAP:Ce, and CRY18 single-crystal scintillators. The presented MTF and DQE characteristics show good imaging properties of the detectors with the YAP:Ce or CRY18 scintillator, especially for a specific type o
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scanning
ISSN
0161-0457
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
384-393
Kód UT WoS článku
000340537200002
EID výsledku v databázi Scopus
—