Innovation possibilities of scintillation electron detector for SEM
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F14%3A00434107" target="_blank" >RIV/68081731:_____/14:00434107 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Innovation possibilities of scintillation electron detector for SEM
Popis výsledku v původním jazyce
To evaluate performance of a scintillation detection system for SEM, it is necessary to consider many scintillator parameters. Various attributes of the scintillator for the SEM electron detector are listed in. The very important parameters are those affecting the detective quantum efficiency (DQE) which is primarily a measure of image noise. Not a less important indicator of image quality is the modulation transfer function (MTF) which describes the ability to show fine image details. Therefore, usinga scanning imaging system, the detector bandwidth, which is given especially by the scintillator decay time, is the key to the good MTF. Currently, the YAG:Ce single crystal scintillator (introduced already in 1978 having somewhat limiting decay characteristic is the most frequently used scintillator in the SEM. The aim of this paper is to outline possibilities of scintillator innovation to get the improved MTF and DQE.
Název v anglickém jazyce
Innovation possibilities of scintillation electron detector for SEM
Popis výsledku anglicky
To evaluate performance of a scintillation detection system for SEM, it is necessary to consider many scintillator parameters. Various attributes of the scintillator for the SEM electron detector are listed in. The very important parameters are those affecting the detective quantum efficiency (DQE) which is primarily a measure of image noise. Not a less important indicator of image quality is the modulation transfer function (MTF) which describes the ability to show fine image details. Therefore, usinga scanning imaging system, the detector bandwidth, which is given especially by the scintillator decay time, is the key to the good MTF. Currently, the YAG:Ce single crystal scintillator (introduced already in 1978 having somewhat limiting decay characteristic is the most frequently used scintillator in the SEM. The aim of this paper is to outline possibilities of scintillator innovation to get the improved MTF and DQE.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
18th International Microscopy Congres. Proceedings
ISBN
978-80-260-6720-7
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Czechoslovak Microscopy Society
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
7. 9. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—