New Method for Automated Disk Diffusion Test
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F14%3A00507186" target="_blank" >RIV/68081731:_____/14:00507186 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/14:PU110974
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
New Method for Automated Disk Diffusion Test
Popis výsledku v původním jazyce
Microbial resistence to antibiotics is a very important parameter in the selection of a proper therapy and in the control of resistence spreading. One of the most used methods for measuring microbial susceptibility is the disk diffusion test. The test is based on diffusion of concentrated antibiotics from paper disk into agar. Concentration of antibiotics in the agar is dependent on distance from the center of the disc. Near antibiotic disc is concentration much higher due difficult permeation of antibiotics in agar. The diffused antibiotics then inhibit growth of sensitive strains. The zones are usually measured manually or by electronic calipers. Several aproaches for automatic inhibition zone detection have been introduced in recent years. Nevertheless, most of the algorithms are based on a similar radial profile analysis. We have designed a novel image-processing algorithm for measuring the size of inhibition zones of antibiotics based on an analysis of corrected image and rated this image with multicriterial algorithms (based on an observation of the radius profile). The algorithm was tested on 100 clinical isolates, resulting in calculation accuracy of 89% (ratio of success computed radii). If we include alternative radii (to be selected manually), the precision of the calculation rises to 98% (tolerance deviations between manual and automatic measurements were 2 mm). The achieved accuracy was independent of the culture medium (e.g., Muller-Hinton, blood agar, chocolate agar). The main advantage of the algorithm is the invariantness to the tested bacterial strain and culture medium. The new algorithm offers an alternative way to determine inhibition zones and evaluate antimicrobial susceptibility.
Název v anglickém jazyce
New Method for Automated Disk Diffusion Test
Popis výsledku anglicky
Microbial resistence to antibiotics is a very important parameter in the selection of a proper therapy and in the control of resistence spreading. One of the most used methods for measuring microbial susceptibility is the disk diffusion test. The test is based on diffusion of concentrated antibiotics from paper disk into agar. Concentration of antibiotics in the agar is dependent on distance from the center of the disc. Near antibiotic disc is concentration much higher due difficult permeation of antibiotics in agar. The diffused antibiotics then inhibit growth of sensitive strains. The zones are usually measured manually or by electronic calipers. Several aproaches for automatic inhibition zone detection have been introduced in recent years. Nevertheless, most of the algorithms are based on a similar radial profile analysis. We have designed a novel image-processing algorithm for measuring the size of inhibition zones of antibiotics based on an analysis of corrected image and rated this image with multicriterial algorithms (based on an observation of the radius profile). The algorithm was tested on 100 clinical isolates, resulting in calculation accuracy of 89% (ratio of success computed radii). If we include alternative radii (to be selected manually), the precision of the calculation rises to 98% (tolerance deviations between manual and automatic measurements were 2 mm). The achieved accuracy was independent of the culture medium (e.g., Muller-Hinton, blood agar, chocolate agar). The main advantage of the algorithm is the invariantness to the tested bacterial strain and culture medium. The new algorithm offers an alternative way to determine inhibition zones and evaluate antimicrobial susceptibility.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PIERS 2014 Guangzhou Proceedings
ISBN
978-1-934142-28-8
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
192-194
Název nakladatele
The Electromagnetics Academy
Místo vydání
Cambridge
Místo konání akce
Guangzhou
Datum konání akce
25. 8. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000393225900037