Cardiac Resynchronization Efficiency Estimation by New Ultra-High-Frequency ECG Dyssynchrony Descriptor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F15%3A00456401" target="_blank" >RIV/68081731:_____/15:00456401 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Cardiac Resynchronization Efficiency Estimation by New Ultra-High-Frequency ECG Dyssynchrony Descriptor
Popis výsledku v původním jazyce
The biventricular implantable pacemaker (BiV) is usually recommended for heart failure patients with LVEF 35 percent and QRS duration > 120ms. We introduce promising marker evaluating suitability and efficiency of the Cardiac Resynchronization Therapy (CRT) recipients. Data: 12-lead UHF-ECG, 25 kHz sampling, 10 minute resting measurement, 28 CRT subjects, each before BiV and with BiV on, VV delay 0. Methods: A new parameter DYS was computed as the time difference between two maxima of UHF envelopes computed from V1 and V6 leads in QRS complex in 500-1000Hz frequency band. The values of DYS and QRS width before and after BiV implantation are analysed. The assumption for being responder for BiV is high value of DYS before CRT and significant DYS decreaseduring biventricular pacing. Subjects with no response on BiV stimulation are under the borderline of DYS = 30ms before stimulation. Thus the DYS parameter can serve as a new marker for the prediction of BiV pacemaker efficiency. This in
Název v anglickém jazyce
Cardiac Resynchronization Efficiency Estimation by New Ultra-High-Frequency ECG Dyssynchrony Descriptor
Popis výsledku anglicky
The biventricular implantable pacemaker (BiV) is usually recommended for heart failure patients with LVEF 35 percent and QRS duration > 120ms. We introduce promising marker evaluating suitability and efficiency of the Cardiac Resynchronization Therapy (CRT) recipients. Data: 12-lead UHF-ECG, 25 kHz sampling, 10 minute resting measurement, 28 CRT subjects, each before BiV and with BiV on, VV delay 0. Methods: A new parameter DYS was computed as the time difference between two maxima of UHF envelopes computed from V1 and V6 leads in QRS complex in 500-1000Hz frequency band. The values of DYS and QRS width before and after BiV implantation are analysed. The assumption for being responder for BiV is high value of DYS before CRT and significant DYS decreaseduring biventricular pacing. Subjects with no response on BiV stimulation are under the borderline of DYS = 30ms before stimulation. Thus the DYS parameter can serve as a new marker for the prediction of BiV pacemaker efficiency. This in
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computing in Cardiology 2015. Vol. 42
ISBN
978-1-5090-0685-4
ISSN
2325-8861
e-ISSN
—
Počet stran výsledku
4
Strana od-do
529-532
Název nakladatele
Computing in Cardiology
Místo vydání
Cambridge
Místo konání akce
Nice
Datum konání akce
6. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—