Popis výsledku v původním jazyce
Cryo-SEM is a technique suitable for observation of frozen biological samples. The cryo-preparation of tissue fragments without using cryo-protectants can destroy intracellular compartments and cytoplasm. On the other hand the use of cryoprotectants can prevent deeper etching of the medium and thus it often leads to more complicated detection of cell membranes, which are important for orientation in the sample during its observation. This can be managed by shadowing of the fractured structures by platinum and it may help to heighten the structures as is done in production of replicas which can give more detail at higher magnification. Here we report how the replicas can be prepared in the device ACE600 (Leica microsystems) equipped with the cryo-attachement and two guns for metal sputtering and carbon evaporation, and the combination of cryo-SEM and replicas.
Název v anglickém jazyce
Processing a Biological Tissue from Cryo-SEM to Replica
Popis výsledku anglicky
Cryo-SEM is a technique suitable for observation of frozen biological samples. The cryo-preparation of tissue fragments without using cryo-protectants can destroy intracellular compartments and cytoplasm. On the other hand the use of cryoprotectants can prevent deeper etching of the medium and thus it often leads to more complicated detection of cell membranes, which are important for orientation in the sample during its observation. This can be managed by shadowing of the fractured structures by platinum and it may help to heighten the structures as is done in production of replicas which can give more detail at higher magnification. Here we report how the replicas can be prepared in the device ACE600 (Leica microsystems) equipped with the cryo-attachement and two guns for metal sputtering and carbon evaporation, and the combination of cryo-SEM and replicas.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Microscopy and Microanalysis
ISSN
1431-9276
e-ISSN
—
Svazek periodika
22
Číslo periodika v rámci svazku
S3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
2
Strana od-do
236-237
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—