Improving DCE-MRI through Unfolded Low-Rank + Sparse Optimisation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F24%3A00636597" target="_blank" >RIV/68081731:_____/24:00636597 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/24:PU152006
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/10635295" target="_blank" >https://ieeexplore.ieee.org/document/10635295</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ISBI56570.2024.10635295" target="_blank" >10.1109/ISBI56570.2024.10635295</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improving DCE-MRI through Unfolded Low-Rank + Sparse Optimisation
Popis výsledku v původním jazyce
A method for perfusion imaging with DCE-MRI is developed based on a combination of two popular paradigms: the low-rank + sparse model for optimisation-based reconstruction, and the deep unfolding. A learnable algorithm derived from a proximal method is designed with emphasis on simplicity and interpretability. The resulting deep network is trained and evaluated using a simulated measurement of a rat with a brain tumor, showing large performance gain over the classical low-rank + sparse baseline. Moreover, a quantitative perfusion analysis is performed based on the reconstructed sequence, proving that even training based on a simple pixel-wise error can lead to a significant improvement of the quality of the perfusion maps.
Název v anglickém jazyce
Improving DCE-MRI through Unfolded Low-Rank + Sparse Optimisation
Popis výsledku anglicky
A method for perfusion imaging with DCE-MRI is developed based on a combination of two popular paradigms: the low-rank + sparse model for optimisation-based reconstruction, and the deep unfolding. A learnable algorithm derived from a proximal method is designed with emphasis on simplicity and interpretability. The resulting deep network is trained and evaluated using a simulated measurement of a rat with a brain tumor, showing large performance gain over the classical low-rank + sparse baseline. Moreover, a quantitative perfusion analysis is performed based on the reconstructed sequence, proving that even training based on a simple pixel-wise error can lead to a significant improvement of the quality of the perfusion maps.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2024 IEEE International Symposium on Biomedical Imaging (ISBI)
ISBN
979-8-3503-1333-8
ISSN
1945-7928
e-ISSN
—
Počet stran výsledku
5
Strana od-do
10635295
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Athens
Datum konání akce
27. 5. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001305705101020