Preparation and pilot experiments on microfluidic chip with surface acoustic waves
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F25%3A00648140" target="_blank" >RIV/68081731:_____/25:00648140 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.spiedigitallibrary.org/conference-proceedings-of-spie/13508/3056740/Preparation-and-pilot-experiments-on-microfluidic-chip-with-surface-acoustic/10.1117/12.3056740.short" target="_blank" >https://www.spiedigitallibrary.org/conference-proceedings-of-spie/13508/3056740/Preparation-and-pilot-experiments-on-microfluidic-chip-with-surface-acoustic/10.1117/12.3056740.short</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1117/12.3056740" target="_blank" >10.1117/12.3056740</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Preparation and pilot experiments on microfluidic chip with surface acoustic waves
Popis výsledku v původním jazyce
This work revolves around preparation of microfluidic chip that can generate surface acoustic wave and standing surface acoustic wave with its own designed frequency. This wave is generated on lithium niobate by interdigital transducers placed directly on the substrate. Chip prepared this way was ready for its primary usage in particles flow manipulation and separation particles in flow by their size. Our pilot measurements included separation, sorting and trapping of polystyrene particles with diameter of 5 and 15 µm. Platform based on surface acoustic wave techniques could be used for biological fluid samples. This platform enables manipulation and study of cells, while preserving their structure, function and biological integrity. Thus, we also studied Trachydiscus minutus as a testing biological cell for trapping. Apart from separation, sorting and trapping, we have observed polystyrene particle accumulation in the field between uniform pair of IDTs.
Název v anglickém jazyce
Preparation and pilot experiments on microfluidic chip with surface acoustic waves
Popis výsledku anglicky
This work revolves around preparation of microfluidic chip that can generate surface acoustic wave and standing surface acoustic wave with its own designed frequency. This wave is generated on lithium niobate by interdigital transducers placed directly on the substrate. Chip prepared this way was ready for its primary usage in particles flow manipulation and separation particles in flow by their size. Our pilot measurements included separation, sorting and trapping of polystyrene particles with diameter of 5 and 15 µm. Platform based on surface acoustic wave techniques could be used for biological fluid samples. This platform enables manipulation and study of cells, while preserving their structure, function and biological integrity. Thus, we also studied Trachydiscus minutus as a testing biological cell for trapping. Apart from separation, sorting and trapping, we have observed polystyrene particle accumulation in the field between uniform pair of IDTs.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
23rd Slovak-Czech-Polish Optical Conference on Wave and Quantum Aspects of Contemporary Optics
ISBN
9781510688087
ISSN
0277-786X
e-ISSN
—
Počet stran výsledku
5
Strana od-do
135080H
Název nakladatele
SPIE
Místo vydání
Bellingham
Místo konání akce
Štrbské Pleso
Datum konání akce
2. 9. 2024
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—