CT Brain Perfusion in the Prediction of Final Infarct Volume: A Prospective Study of Different Software Settings for Acute Ischemic Core Calculation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081740%3A_____%2F22%3A00562261" target="_blank" >RIV/68081740:_____/22:00562261 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00064173:_____/22:43924022 RIV/00216208:11120/22:43924022 RIV/00216208:11130/22:10448508
Výsledek na webu
<a href="https://www.mdpi.com/2075-4418/12/10/2290" target="_blank" >https://www.mdpi.com/2075-4418/12/10/2290</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/diagnostics12102290" target="_blank" >10.3390/diagnostics12102290</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CT Brain Perfusion in the Prediction of Final Infarct Volume: A Prospective Study of Different Software Settings for Acute Ischemic Core Calculation
Popis výsledku v původním jazyce
CT perfusion (CTP) is used for the evaluation of brain tissue viability in patients with acute ischemic stroke (AIS). We studied the accuracy of three different syngo.via software (SW) settings for acute ischemic core estimation in predicting the final infarct volume (FIV). The ischemic core was defined as follows: Setting A: an area with cerebral blood flow (CBF) < 30% compared to the contralateral healthy hemisphere. Setting B: CBF < 20% compared to contralateral hemisphere. Setting C: area of cerebral blood volume (CBV) < 1.2 mL/100 mL. We studied 47 AIS patients (aged 68 ± 11.2 years) with large vessel occlusion in the anterior circulation, treated in the early time window (up to 6 h), who underwent technically successful endovascular thrombectomy (EVT). FIV was measured on MRI performed 24 ± 2 h after EVT. In general, all three settings correlated with each other, however, the absolute agreement between acute ischemic core volume on CTP and FIV on MRI was poor, intraclass correlation for all three settings was between 0.64 and 0.69, root mean square error of the individual observations was between 58.9 and 66.0. Our results suggest that using CTP syngo.via SW for prediction of FIV in AIS patients in the early time window is not appropriate.
Název v anglickém jazyce
CT Brain Perfusion in the Prediction of Final Infarct Volume: A Prospective Study of Different Software Settings for Acute Ischemic Core Calculation
Popis výsledku anglicky
CT perfusion (CTP) is used for the evaluation of brain tissue viability in patients with acute ischemic stroke (AIS). We studied the accuracy of three different syngo.via software (SW) settings for acute ischemic core estimation in predicting the final infarct volume (FIV). The ischemic core was defined as follows: Setting A: an area with cerebral blood flow (CBF) < 30% compared to the contralateral healthy hemisphere. Setting B: CBF < 20% compared to contralateral hemisphere. Setting C: area of cerebral blood volume (CBV) < 1.2 mL/100 mL. We studied 47 AIS patients (aged 68 ± 11.2 years) with large vessel occlusion in the anterior circulation, treated in the early time window (up to 6 h), who underwent technically successful endovascular thrombectomy (EVT). FIV was measured on MRI performed 24 ± 2 h after EVT. In general, all three settings correlated with each other, however, the absolute agreement between acute ischemic core volume on CTP and FIV on MRI was poor, intraclass correlation for all three settings was between 0.64 and 0.69, root mean square error of the individual observations was between 58.9 and 66.0. Our results suggest that using CTP syngo.via SW for prediction of FIV in AIS patients in the early time window is not appropriate.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
50101 - Psychology (including human - machine relations)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Diagnostics
ISSN
2075-4418
e-ISSN
2075-4418
Svazek periodika
12
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
10
Strana od-do
2290
Kód UT WoS článku
000872352500001
EID výsledku v databázi Scopus
2-s2.0-85140627573