Calibration and quantification of fast intracellular motion (FIM) in living cells using correlation analysis.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378050%3A_____%2F03%3A23033091" target="_blank" >RIV/68378050:_____/03:23033091 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calibration and quantification of fast intracellular motion (FIM) in living cells using correlation analysis.
Popis výsledku v původním jazyce
Video Rate Confocal Laser Scanning Microscope (VRCLSM) Odyssey (Noran, Middleton, WI, USA) at the highest spatial and temporal resolution of back scattered light (BSL) imaging enabled regular observation of fast intracellular motion (FIM) first revealedin living neoplastic cells. However, the absence of an objective evaluation has hampered further study of the mechanisms and biological significance of FIM. A search for a suitable method led to correlation analysis. It was calibrated on Brownian motionand a known type of motion such as cell marginal ruffling compared with FIM. Therefore, several crucial incidences of FIM could be analyzed. Apart from an argument against viewing FIM as a manifestation of simple Brownian motion, the correlation analysisof FIM in the adjacent peripheries of a rat fibroblast and a K4 rat sarcoma cell confirmed the notion of higher and uneven distribution of velocity of FIM in a tumor cell so far shown in color coded images only.
Název v anglickém jazyce
Calibration and quantification of fast intracellular motion (FIM) in living cells using correlation analysis.
Popis výsledku anglicky
Video Rate Confocal Laser Scanning Microscope (VRCLSM) Odyssey (Noran, Middleton, WI, USA) at the highest spatial and temporal resolution of back scattered light (BSL) imaging enabled regular observation of fast intracellular motion (FIM) first revealedin living neoplastic cells. However, the absence of an objective evaluation has hampered further study of the mechanisms and biological significance of FIM. A search for a suitable method led to correlation analysis. It was calibrated on Brownian motionand a known type of motion such as cell marginal ruffling compared with FIM. Therefore, several crucial incidences of FIM could be analyzed. Apart from an argument against viewing FIM as a manifestation of simple Brownian motion, the correlation analysisof FIM in the adjacent peripheries of a rat fibroblast and a K4 rat sarcoma cell confirmed the notion of higher and uneven distribution of velocity of FIM in a tumor cell so far shown in color coded images only.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EA - Morfologické obory a cytologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA304%2F99%2F0368" target="_blank" >GA304/99/0368: Význam rychlých vnitrobuněčných motilitních reakcí živých buněk</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
SCANNING
ISSN
0161-0457
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
N/A
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
10
Strana od-do
230-239
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—