Modifikace materiálů ionty velkých energiích emitovaných z laserem generovaného plazmatu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F05%3A00028677" target="_blank" >RIV/68378271:_____/05:00028677 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modification of materials by high energy plasma ions
Popis výsledku v původním jazyce
The high-power iodine laser of the Prague Asterix Laser System (PALS), emitting radiation at 438 nm wavelength, 400 ps pulse duration and about 250 Jmaximum pulse energy, was employed to irradiate in vacuum a germanium target. The amount, the energy andthe charge state of the ions emitted from the laser-produced plasma are analyzed by time-of-flight measurements performed with the use of ion collectors (ICs) and an electrostatic ion energy analyzer (IEA). Energetic Ge ions emitted from the laser-produced plasma were directly implanted into C substrates placed at 30 cm distance from the target and 30o angle with respect to the normal to the target surface. The implantation depths and implanted doses were analyzed by two different techniques: the Rutherford backscattering spectrometry (RBS) and the laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS
Název v anglickém jazyce
Modification of materials by high energy plasma ions
Popis výsledku anglicky
The high-power iodine laser of the Prague Asterix Laser System (PALS), emitting radiation at 438 nm wavelength, 400 ps pulse duration and about 250 Jmaximum pulse energy, was employed to irradiate in vacuum a germanium target. The amount, the energy andthe charge state of the ions emitted from the laser-produced plasma are analyzed by time-of-flight measurements performed with the use of ion collectors (ICs) and an electrostatic ion energy analyzer (IEA). Energetic Ge ions emitted from the laser-produced plasma were directly implanted into C substrates placed at 30 cm distance from the target and 30o angle with respect to the normal to the target surface. The implantation depths and implanted doses were analyzed by two different techniques: the Rutherford backscattering spectrometry (RBS) and the laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physical Research. B
ISSN
0168-583X
e-ISSN
—
Svazek periodika
240
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
229-233