Effects of high-energy particle showers on the embedded front-end electronics of an electromagnetic calorimeter for a future lepton collider
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F11%3A00371868" target="_blank" >RIV/68378271:_____/11:00371868 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.nima.2011.06.056" target="_blank" >http://dx.doi.org/10.1016/j.nima.2011.06.056</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2011.06.056" target="_blank" >10.1016/j.nima.2011.06.056</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effects of high-energy particle showers on the embedded front-end electronics of an electromagnetic calorimeter for a future lepton collider
Popis výsledku v původním jazyce
Application Speci c Integrated Circuits, ASICs, similar to those invisaged for the readout electronics of the central calorimeters of detectors for a future lepton collider have been exposed to high-energy electromagnetic showers. A salient feature of these calorimeters is that the readout electronics will be embedded into the calorimeter layers. In this article it is shown that interactions of shower particles in the volume of the readout electronics do not alter the noise pattern of the ASICs. No signal at or above the MIP level has been observed during the exposure. The upper limit at the 95% con dence level on the frequency of faked signals is smaller than 10-5 for a noise threshold of about 60% of a MIP. For ASICs with similar design to those which were tested, it can thus be largely excluded that the embedding of the electronics into the calorimeter layers compromises the performance of the calorimeters.
Název v anglickém jazyce
Effects of high-energy particle showers on the embedded front-end electronics of an electromagnetic calorimeter for a future lepton collider
Popis výsledku anglicky
Application Speci c Integrated Circuits, ASICs, similar to those invisaged for the readout electronics of the central calorimeters of detectors for a future lepton collider have been exposed to high-energy electromagnetic showers. A salient feature of these calorimeters is that the readout electronics will be embedded into the calorimeter layers. In this article it is shown that interactions of shower particles in the volume of the readout electronics do not alter the noise pattern of the ASICs. No signal at or above the MIP level has been observed during the exposure. The upper limit at the 95% con dence level on the frequency of faked signals is smaller than 10-5 for a noise threshold of about 60% of a MIP. For ASICs with similar design to those which were tested, it can thus be largely excluded that the embedding of the electronics into the calorimeter layers compromises the performance of the calorimeters.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BF - Elementární částice a fyzika vysokých energií
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research Section A
ISSN
0168-9002
e-ISSN
—
Svazek periodika
654
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
13
Strana od-do
97-109
Kód UT WoS článku
000295765100015