Antibacterial coatings for biomedical applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F18%3A00501090" target="_blank" >RIV/68378271:_____/18:00501090 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1007/978-94-024-1298-7_46" target="_blank" >https://doi.org/10.1007/978-94-024-1298-7_46</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-94-024-1298-7_46" target="_blank" >10.1007/978-94-024-1298-7_46</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Antibacterial coatings for biomedical applications
Popis výsledku v původním jazyce
Diamond like carbon (DLC) and Ag-doped DLC (Ag-DLC) films were prepared by dual pulsed laser deposition using graphite and silver targets and two KrF excimer lasers. The silver concentration in the films was varied from 1.1 to 9.3 at. %. The surface topography was analysed by atomic force microscopy. The pure DLC was very smooth, but the roughness increased with rising silver content. Ethylene glycol, diiodomethane and deionized water were used to measure contact angles (CA). The measurements for water showed that the CA of Ag-DLC films (78–98 ) was higher than that of the DLC film (77 ). In order to understand the influence of incorporated Ag on the wettability, the surface energy and the protein adsorption as an indirect measure of the hemocompatibility were calculated. The surface energy of DLC and Ag-DLC films was same.
Název v anglickém jazyce
Antibacterial coatings for biomedical applications
Popis výsledku anglicky
Diamond like carbon (DLC) and Ag-doped DLC (Ag-DLC) films were prepared by dual pulsed laser deposition using graphite and silver targets and two KrF excimer lasers. The silver concentration in the films was varied from 1.1 to 9.3 at. %. The surface topography was analysed by atomic force microscopy. The pure DLC was very smooth, but the roughness increased with rising silver content. Ethylene glycol, diiodomethane and deionized water were used to measure contact angles (CA). The measurements for water showed that the CA of Ag-DLC films (78–98 ) was higher than that of the DLC film (77 ). In order to understand the influence of incorporated Ag on the wettability, the surface energy and the protein adsorption as an indirect measure of the hemocompatibility were calculated. The surface energy of DLC and Ag-DLC films was same.
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
—
OECD FORD obor
10302 - Condensed matter physics (including formerly solid state physics, supercond.)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Advanced nanotechnologies for detection and defence against CBRN agents
ISBN
978-9402412970
Počet stran výsledku
10
Strana od-do
467-476
Počet stran knihy
512
Název nakladatele
Springer International Edition
Místo vydání
Cham
Kód UT WoS kapitoly
—