The LIDRAE water-Cherenkov air shower array
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F18%3A00549840" target="_blank" >RIV/68378271:_____/18:00549840 - isvavai.cz</a>
Výsledek na webu
<a href="https://pos.sissa.it/301/439/pdf" target="_blank" >https://pos.sissa.it/301/439/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22323/1.301.0439" target="_blank" >10.22323/1.301.0439</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The LIDRAE water-Cherenkov air shower array
Popis výsledku v původním jazyce
We present the design, and preliminary results of the LIDRAE water-Cherenkov air shower array installed at UFABC (23.6∘S, 46.5∘W, 750 m a.s.l.). LIDRAE detects the particles of extensive air showers with energies exceeding 100 TeV and is able to measure the arrival direction and energy of the primary cosmic rays. The array is composed of three tanks each filled with one thousand liters of water with a large aperture photomultiplier on the top cover of each tank overlooking the water volume. The photomultipliers detect the Cherenkov light generated by the passage of ultrarelativistic charged particles through the water. The produced signals are then sent to the data acquisition electronics where they are amplified, formatted, digitized and stored. The data are recorded in single and triple coincidence modes.
Název v anglickém jazyce
The LIDRAE water-Cherenkov air shower array
Popis výsledku anglicky
We present the design, and preliminary results of the LIDRAE water-Cherenkov air shower array installed at UFABC (23.6∘S, 46.5∘W, 750 m a.s.l.). LIDRAE detects the particles of extensive air showers with energies exceeding 100 TeV and is able to measure the arrival direction and energy of the primary cosmic rays. The array is composed of three tanks each filled with one thousand liters of water with a large aperture photomultiplier on the top cover of each tank overlooking the water volume. The photomultipliers detect the Cherenkov light generated by the passage of ultrarelativistic charged particles through the water. The produced signals are then sent to the data acquisition electronics where they are amplified, formatted, digitized and stored. The data are recorded in single and triple coincidence modes.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
—
Návaznosti
—
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of Science
ISBN
—
ISSN
1824-8039
e-ISSN
—
Počet stran výsledku
7
Strana od-do
1-7
Název nakladatele
Sissa Medilab srl
Místo vydání
Trieste
Místo konání akce
Busan
Datum konání akce
10. 7. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—