Maghemite nanoparticles coated by methacrylamide-based polymer for magnetic particle imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68378271%3A_____%2F21%3A00539851" target="_blank" >RIV/68378271:_____/21:00539851 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61389013:_____/21:00539851 RIV/00216208:11110/21:10427484 RIV/00216208:11320/21:10427484 RIV/60461373:22340/21:43922106
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s11051-021-05164-x" target="_blank" >https://link.springer.com/article/10.1007/s11051-021-05164-x</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s11051-021-05164-x" target="_blank" >10.1007/s11051-021-05164-x</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Maghemite nanoparticles coated by methacrylamide-based polymer for magnetic particle imaging
Popis výsledku v původním jazyce
A wise selection of tracers is critical for magnetic particle imaging (MPI). Most of the current tracers are based on superparamagnetic iron oxide nanoparticles (SPIONs) with a suitable coating. We prepared maghemite cores (γ-Fe2O3) by coprecipitation of Fe(II) and Fe(III) salts with ammonium hydroxide followed by oxidation with hydrogen peroxide and stabilization as an anionic (γ-Fe2O3⊖) or cationic colloid (γ-Fe2O3⨁). The cores were coated by poly(N-(2-hydroxypropyl)methacrylamide)-co-N-[2-(hydroxyamino)-2-oxo-ethyl]-2-methyl-prop-2-enamide. The particles were characterized by dynamic light scattering, transmission electron microscopy, X-ray diffraction, Mössbauer spectroscopy, tested in vitro in a field-free point MPI scanner, and compared to nanoparticles prepared by oxidation with sodium hypochlorite and to the commercially available Resovist®. The cores had an average diameter of 8.0 nm (γ-Fe2O3⨁) and 8.7 nm (γ-Fe2O3⊖). The hydrodynamic diameter was 88 nm. Zeta potential values for both positively charged (+52 mV) and negatively charged particles (–60 mV) provided for good colloidal stabilization. Spinel structure of maghemite was confirmed by Mössbauer spectroscopy. The uncoated γ-Fe2O3⨁ particles yielded an MPI signal lower (by 16 %) than Resovist. The coated ones reached 88 % of the Resovist signal. Anionic γ-Fe2O3⊖ particles reached a higher (uncoated particles, by 15 %) or comparable (coated ones) signal relative to Resovist with a substantially lower signal dispersion. Control particles prepared by oxidation with sodium hypochlorite scored the weakest results. To conclude, a suitable size, narrow size distribution, and colloidal stability predispose the synthetized particles for use as a tracer for MPI. The anionic particles provided a higher signal with a lower dispersion than commercial tracers.
Název v anglickém jazyce
Maghemite nanoparticles coated by methacrylamide-based polymer for magnetic particle imaging
Popis výsledku anglicky
A wise selection of tracers is critical for magnetic particle imaging (MPI). Most of the current tracers are based on superparamagnetic iron oxide nanoparticles (SPIONs) with a suitable coating. We prepared maghemite cores (γ-Fe2O3) by coprecipitation of Fe(II) and Fe(III) salts with ammonium hydroxide followed by oxidation with hydrogen peroxide and stabilization as an anionic (γ-Fe2O3⊖) or cationic colloid (γ-Fe2O3⨁). The cores were coated by poly(N-(2-hydroxypropyl)methacrylamide)-co-N-[2-(hydroxyamino)-2-oxo-ethyl]-2-methyl-prop-2-enamide. The particles were characterized by dynamic light scattering, transmission electron microscopy, X-ray diffraction, Mössbauer spectroscopy, tested in vitro in a field-free point MPI scanner, and compared to nanoparticles prepared by oxidation with sodium hypochlorite and to the commercially available Resovist®. The cores had an average diameter of 8.0 nm (γ-Fe2O3⨁) and 8.7 nm (γ-Fe2O3⊖). The hydrodynamic diameter was 88 nm. Zeta potential values for both positively charged (+52 mV) and negatively charged particles (–60 mV) provided for good colloidal stabilization. Spinel structure of maghemite was confirmed by Mössbauer spectroscopy. The uncoated γ-Fe2O3⨁ particles yielded an MPI signal lower (by 16 %) than Resovist. The coated ones reached 88 % of the Resovist signal. Anionic γ-Fe2O3⊖ particles reached a higher (uncoated particles, by 15 %) or comparable (coated ones) signal relative to Resovist with a substantially lower signal dispersion. Control particles prepared by oxidation with sodium hypochlorite scored the weakest results. To conclude, a suitable size, narrow size distribution, and colloidal stability predispose the synthetized particles for use as a tracer for MPI. The anionic particles provided a higher signal with a lower dispersion than commercial tracers.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
21001 - Nano-materials (production and properties)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
—
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Nanoparticle Research
ISSN
1388-0764
e-ISSN
1572-896X
Svazek periodika
23
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
15
Strana od-do
52
Kód UT WoS článku
000620932000003
EID výsledku v databázi Scopus
2-s2.0-85101277773